Combination of Injection Volume Calibration by Creatinine and MS Signals’ Normalization to Overcome Urine Variability in LC-MS-Based Metabolomics Studies
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
It is essential to choose one preprocessing method for liquid chromatography-mass spectrometry (LC-MS)-based metabolomics studies of urine samples in order to overcome their variability. However, the commonly used normalization methods do not substantially reduce the high variabilities arising from differences in urine concentration, especially for signal saturation (abundant metabolites exceed the dynamic range of the instrumentation) or missing values. Herein, a simple preacquisition strategy based on differential injection volumes calibrated by creatinine (to reduce the concentration differences between the samples), combined with normalization to "total useful MS signals" or "all MS signals", is proposed to overcome urine variabilities. This strategy was first systematically compared with other popular normalization methods by application to serially diluted urine samples. Then, the method has been verified using rat urine samples of pre- and postinoculation of Walker 256 carcinoma cells. The results showed that the calibration of injection volumes based on creatinine values could effectively eliminate intragroup differences caused by variations in the concentrations of urinary metabolites, thus giving better parallelism and clustering effects. In addition, peak area normalization could further eliminate intraclass differences. Therefore, the strategy of combining peak area normalization with calibration of injection volumes of urine samples based on their creatinine values is effective for solving problems associated with urinary metabolomics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
van den Berg, R. A., Hoefsloot, H. C., Westerhuis, J. A., Smilde, A. K., & van der Werf, M. J. (2006) · BMC Genomics · doi:10.1186/1471-2164-7-142 · Cited by 2,450
Cited by
Thévenot, E. A., Roux, A., Xu, Y., Ezan, E., & Junot, C. (2015) · Journal of Proteome Research · doi:10.1021/acs.jproteome.5b00354 · Cited by 1,735
Colonic transit time is related to bacterial metabolism and mucosal turnover in the gut
Roager, H. M., Hansen, L. B. S., Bahl, M. I., Frandsen, H. L., Carvalho, V., Gøbel, R. J., Dalgaard, M. D., Plichta, D. R., Sparholt, M. H., Vestergaard, H., et al. (2016) · Nature Microbiology · doi:10.1038/nmicrobiol.2016.93 · Cited by 449
Sample normalization methods in quantitative metabolomics
Wu, Y., & Li, L. (2016) · Journal of Chromatography A · doi:10.1016/j.chroma.2015.12.007 · Cited by 280
Metabolomic analysis of urine samples by UHPLC-QTOF-MS: Impact of normalization strategies
Gagnebin, Y., Tonoli, D., Lescuyer, P., Ponte, B., de Seigneux, S., Martin, P.-Y., Schappler, J., Boccard, J., & Rudaz, S. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.12.029 · Cited by 203
Metabolomic profiling of single enlarged lysosomes
Zhu, H., Li, Q., Liao, T., Yin, X., Chen, Q., Wang, Z., Dai, M., Yi, L., Ge, S., Miao, C., et al. (2021) · Nature Methods · doi:10.1038/s41592-021-01182-8 · Cited by 103
Metadata
- Authors
- Chen, Y., Shen, G., Zhang, R., He, J., Zhang, Y., Xu, J., Yang, W., Chen, X., Song, Y., & Abliz, Z.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-08-02
- Volume
- 85
- Issue
- 16
- Pages
- 7659-7665
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1991778398
- Cited by
- 69
- References
- 1
- FWCI
- 2.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.