The DOI matches its Crossref record.
Three-Dimensional Paper-Based Microfluidic Device for Assays of Protein and Glucose in Urine
Abstract
The first step in curing a disease is being able to detect the disease effectively. Paper-based microfluidic devices are biodegradable and can make diagnosing diseases cost-effective and easy in almost all environments. We created a three-dimesnional (3D) paper device using wax printing fabrication technique and basic principles of origami. This design allows for a versatile fabrication technique over previously reported patterning of SU-8 photoresist on chromatography paper by employing a readily available wax printer. The design also utilizes multiple colorimetric assays that can accommodate one or more analytes including urine, blood, and saliva. In this case to demonstrate the functionality of the 3D paper-based microfluidic system, a urinalysis of protein and glucose assays is conducted. The amounts of glucose and protein introduced to the device are found to be proportional to the color change of each assay. This color change was quantified by use of Adobe Photoshop. Urine samples from participants with no pre-existing health conditions and one person with diabetes were collected and compared against synthetic urine samples with predetermined glucose and protein levels. Utilizing this method, we were able to confirm that both protein and glucose levels were in fact within healthy ranges for healthy participants. For the participant with diabetes, glucose was found to be above the healthy range while the protein level was in the healthy range.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Recent Developments in Paper-Based Microfluidic Devices
Cate, D. M., Adkins, J. A., Mettakoonpitak, J., & Henry, C. S. (2015) · Analytical Chemistry · doi:10.1021/ac503968p · Cited by 1,236
Turning the Page: Advancing Paper-Based Microfluidics for Broad Diagnostic Application
Gong, M. M., & Sinton, D. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00024 · Cited by 573
Paper-based microfluidics: Simplified fabrication and assay methods
Nishat, S., Jafry, A. T., Martinez, A. W., & Awan, F. R. (2021) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2021.129681 · Cited by 392
Li, J., Rossignol, F., & Macdonald, J. (2015) · Lab on a Chip · doi:10.1039/c5lc00235d · Cited by 307
Paper-Based Sensors: Emerging Themes and Applications
Singh, A. T., Lantigua, D., Meka, A., Taing, S., Pandher, M., & Camci-Unal, G. (2018) · Sensors · doi:10.3390/s18092838 · Cited by 284
Metadata
- Authors
- Sechi, D., Greer, B., Johnson, J., & Hashemi, N.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-11-11
- Volume
- 85
- Issue
- 22
- Pages
- 10733-10737
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2072821145
- Cited by
- 169
- References
- 0
- FWCI
- 7.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Three-Dimensional Paper-Based Microfluidic Device for Assays of Protein and Glucose in Urine. https://app.cochat.ai/papers/10.1021/ac4014868
- The paper
- Sechi, D., Greer, B., Johnson, J., & Hashemi, N. (2013). Three-Dimensional Paper-Based Microfluidic Device for Assays of Protein and Glucose in Urine. Analytical Chemistry. https://doi.org/10.1021/ac4014868
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.