CoChat

High-Sensitivity LC-MS/MS Quantification of Peptides and Proteins in Complex Biological Samples: The Impact of Enzymatic Digestion and Internal Standard Selection on Method Performance

Open access
Bronsema, Kees J., Bischoff, Rainer, van de Merbel, Nico C. · 2013 · Analytical Chemistry
Cited by 90

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Two important aspects of peptide and protein quantification by LC-MS/MS, the enzymatic digestion step and the internal standardization approach, were systematically investigated with a small protein, salmon calcitonin, which could be analyzed both without and with digestion. Quantification of undigested salmon calcitonin, after solid-phase extraction from plasma, resulted in a lower limit of quantification of 10 pg/mL, while introduction of a tryptic digestion step, followed by quantification of a signature peptide, increased this to 50 pg/mL. The sensitivity was reduced by interferences in the selected reaction monitoring (SRM) transition of the signature peptide due to the increase in sample complexity caused by the digestion and a less selective SRM transition of the signature peptide as compared to undigested salmon calcitonin. Eight internal standardization approaches were compared with respect to accuracy and precision in workflows with and without digestion. Analogue and stable-isotope-labeled (SIL) internal standards were evaluated including an in-house created (18)O-labeled peptide, a cleavable SIL peptide, and an internal standard created by differential derivatization of the signature peptide. We conclude that the best internal standard for the workflows both with and without digestion was the SIL form of the analyte, although the use of several SIL signature peptides and a differentially derivatized signature peptide also resulted in methods with performances which meet the FDA guidelines.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac4015116

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 90

Metadata

Authors
Bronsema, K. J., Bischoff, R., & van de Merbel, N. C.
Venue
Analytical Chemistry
Published
2013-09-25
Volume
85
Issue
20
Pages
9528-9535
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2067529588
Cited by
90
References
1
FWCI
3.57
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High-Sensitivity LC-MS/MS Quantification of Peptides and Proteins in Complex Biological Samples: The Impact of Enzymatic Digestion and Internal Standard Selection on Method Performance. https://app.cochat.ai/papers/10.1021/ac4015116
The paper
Bronsema, K. J., Bischoff, R., & van de Merbel, N. C. (2013). High-Sensitivity LC-MS/MS Quantification of Peptides and Proteins in Complex Biological Samples: The Impact of Enzymatic Digestion and Internal Standard Selection on Method Performance. Analytical Chemistry. https://doi.org/10.1021/ac4015116

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.