Recommendations for Validation of LC-MS/MS Bioanalytical Methods for Protein Biotherapeutics
Open accessAbstract
This paper represents the consensus views of a cross-section of companies and organizations from the USA and Canada regarding the validation and application of liquid chromatography tandem mass spectrometry (LC-MS/MS) methods for bioanalysis of protein biotherapeutics in regulated studies. It was prepared under the auspices of the AAPS Bioanalytical Focus Group's Protein LC-MS Bioanalysis Subteam and is intended to serve as a guide to drive harmonization of best practices within the bioanalytical community and provide regulators with an overview of current industry thinking on applying LC-MS/MS technology for protein bioanalysis. For simplicity, the scope was limited to the most common current approach in which the protein is indirectly quantified using LC-MS/MS measurement of one or more of its surrogate peptide(s) produced by proteolytic digestion. Within this context, we considered a range of sample preparation approaches from simple in-matrix protein denaturation and digestion to complex procedures involving affinity capture enrichment. Consideration was given to the method validation experiments normally associated with traditional LC-MS/MS and ligand-binding assays. Our collective experience, thus far, is that LC-MS/MS methods for protein bioanalysis require different development and validation considerations than those used for small molecules. The method development and validation plans need to be tailored to the particular assay format being established, taking into account a number of important factors: the intended use of the assay, the test species or study population, the characteristics of the protein biotherapeutic and its similarity to endogenous proteins, potential interferences, as well as the nature, quality, and availability of reference and internal standard materials.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
LC-MS/MS methods also have problems with sample matrix interference.
“Such methods also have problems with sample matrix interference 124.”
From Measuring Oxytocin and Vasopressin: Bioassays, Immunoassays and Random Numbers (2016) · cites this paper as [124]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Ong, S.-E., Blagoev, B., Kratchmarova, I., Kristensen, D. B., Steen, H., Pandey, A., & Mann, M. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m200025-mcp200 · Cited by 5,574 · see citing works
Desilva, B. S., Smith, W. C., WEINER, R. S., Kelley, M. M., Smolec, J., Lee, B., Khan, M., Tacey, R. L., Hill, H. M., & Celniker, A. C. (2003) · Pharmaceutical Research · doi:10.1023/b:pham.0000003390.51761.3d · Cited by 624 · see citing works
European Medicines Agency Guideline on Bioanalytical Method Validation: What More Is There to Say?
Smith, G. (2012) · Bioanalysis · doi:10.4155/bio.12.44 · Cited by 308 · see citing works
In Vivo Deamidation Characterization of Monoclonal Antibody by LC/MS/MS
Huang, L., Lu, J., Wroblewski, V. J., Beals, J. M., & Riggin, R. M. (2005) · Analytical Chemistry · doi:10.1021/ac0494174 · Cited by 266 · see citing works
Bioanalytical Assay Strategies for The Development of Antibody–Drug Conjugate Biotherapeutics
Kaur, S., Xu, K., Saad, O. M., Dere, R. C., & Carrasco‐Triguero, M. (2013) · Bioanalysis · doi:10.4155/bio.12.299 · Cited by 237 · see citing works
Self-citationBioanalytical LC–MS/MS of protein-based biopharmaceuticals
van den Broek, I., Niessen, W. M. A., & van Dongen, W. D. (2013) · Journal of Chromatography B · doi:10.1016/j.jchromb.2013.04.030 · Cited by 231 · see citing works
Heudi, O., Barteau, S., Zimmer, D., et al. (2008) · Analytical Chemistry · doi:10.1021/ac800205s · Cited by 230 · see citing works
Li, H., Ortiz, R., Tran, L. T., et al. (2012) · Analytical Chemistry · doi:10.1021/ac202792n · Cited by 194 · see citing works
Gorovits, B., Alley, S. C., Bilic, S., et al. (2013) · Bioanalysis · doi:10.4155/bio.13.38 · Cited by 171 · see citing works
Bronsema, K. J., Bischoff, R., & van de Merbel, N. C. (2012) · Journal of Chromatography B · doi:10.1016/j.jchromb.2012.02.021 · Cited by 148 · see citing works
Yang, Z., Hayes, M., Fang, X., et al. (2007) · Analytical Chemistry · doi:10.1021/ac0712502 · Cited by 140 · see citing works
Self-citationBooth, B. P., Arnold, M. E., Desilva, B. S., Amaravadi, L. S., Dudal, S., Fluhler, E., Gorovits, B., Haidar, S. H., Kadavil, J., Lowes, S., et al. (2014) · The AAPS Journal · doi:10.1208/s12248-014-9696-2 · Cited by 115 · see citing works
Bronsema, K. J., Bischoff, R., & van de Merbel, N. C. (2013) · Analytical Chemistry · doi:10.1021/ac4015116 · Cited by 90 · see citing works
Jiang, H., Zeng, J., Titsch, C., Voronin, K., Akinsanya, B., Luo, L., Shen, H., Desai, D. D., Allentoff, A. J., Aubry, A., et al. (2013) · Analytical Chemistry · doi:10.1021/ac402420v · Cited by 84 · see citing works
Self-citationStaack, R. F., Stracke, J. O., Stubenrauch, K. G., et al. (2011) · Bioanalysis · doi:10.4155/bio.11.16 · Cited by 78 · see citing works
King, L. E., Farley, E., Imazato, M., Keefe, J., Khan, M., Ma, M., Pihl, K. S., & Sriraman, P. (2014) · The AAPS Journal · doi:10.1208/s12248-014-9583-x · Cited by 72 · see citing works
Xu, K., Liu, L., Maia, M., et al. (2014) · Bioanalysis · doi:10.4155/bio.14.142 · Cited by 71 · see citing works
Self-citationJi, C., Sadagopan, N., Zhang, Y., & Lepsy, C. S. (2009) · Analytical Chemistry · doi:10.1021/ac901800f · Cited by 65 · see citing works
Self-citationLi, H., Ortiz, R., Tran, L. T., et al. (2012) · The AAPS Journal · doi:10.1208/s12248-012-9435-5 · Cited by 63 · see citing works
Hall, M. P., Gegg, C. V., Walker, K. W., Spahr, C. S., Ortiz, R., Patel, V., Yu, S., Zhang, L., Lu, H. S., Desilva, B. S., et al. (2010) · The AAPS Journal · doi:10.1208/s12248-010-9218-9 · Cited by 59 · see citing works
Self-citationKnutsson, M., Schmidt, R., & Timmerman, P. (2013) · Bioanalysis · doi:10.4155/bio.13.193 · Cited by 36 · see citing works
Dufield, D. R., & Radabaugh, M. R. (2011) · Methods · doi:10.1016/j.ymeth.2011.08.012 · Cited by 36 · see citing works
Self-citationDawes, M. L., Gu, H., Wang, J., Schuster, A. E., & Haulenbeek, J. R. (2013) · Journal of Chromatography B · doi:10.1016/j.jchromb.2013.06.027 · Cited by 22 · see citing works
Wang, Y., & Heilig, J. S. (2012) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2012.06.018 · Cited by 19 · see citing works
Pitfalls in Protein Quantitation Using Acid-Catalyzed O18 Labeling: Hydrolysis-Driven Deamidation
Wang, S., Bobst, C. E., & Kaltashov, I. A. (2011) · Analytical Chemistry · doi:10.1021/ac201657u · Cited by 19 · see citing works
Manuilov, A. V., Radziejewski, C. H., & Lee, D. H. (2011) · mAbs · doi:10.4161/mabs.3.4.16237 · Cited by 17 · see citing works
Gonzalez, A., Cubrinovski, M., Pidwerbesky, B., et al. (2012) · Revista de ingeniería de construcción · doi:10.4067/s0718-50732012000200001 · Cited by 2 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Measuring Oxytocin and Vasopressin: Bioassays, Immunoassays and Random Numbers
Leng, G., & Sabatier, N. (2016) · Journal of Neuroendocrinology · doi:10.1111/jne.12413 · Cited by 237 · see citing works
“Such methods also have problems with sample matrix interference (124).”
Neubert, H., Shuford, C. M., Olah, T. V., Garofolo, F., Schultz, G. A., Jones, B. R., Amaravadi, L., Laterza, O. F., Xu, K., & Ackermann, B. L. (2020) · Clinical Chemistry · doi:10.1093/clinchem/hvz022 · Cited by 109 · see citing works
Self-citationMeng, L., Chan, E. W., Ng, C., Aimi, J., Tran, J. C., Oh, A. J., Merchant, M., Purkey, H. E., Heffron, T. P., Kaur, S., et al. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.2c03146 · Cited by 15 · see citing works
Self-citation
- Authors
- Jenkins, R., Duggan, J. X., Aubry, A.-F., Zeng, J., Lee, J. W., Cojocaru, L., Dufield, D., Garofolo, F., Kaur, S., Schultz, G. A., Xu, K., Yang, Z., Yu, J., Zhang, Y. J., & Vazvaei, F.
- Affiliations
- Pharmaceutical Product Development (United States) (US)
- Boehringer Ingelheim (United States) (US)
- Bristol-Myers Squibb (United States) (US)
- Pfizer (United States) (US)
- Genentech (US)
- IQVIA (United Kingdom) (GB)
- Corresponding author
- Vazvaei, Faye
- Venue
- The AAPS Journal
- Published
- 2014-11-13
- Volume
- 17
- Issue
- 1
- Pages
- 1-16
- ISSN
- 1550-7416 (ISSN-L)
- PMC
- PMC4287296
- OpenAlex
- W1964595219
- Cited by
- 181
- References
- 27
- Citations by year
- 2026: 9 · 2025: 11 · 2024: 15 · 2023: 9 · 2022: 9 · 2021: 14 · 2020: 18 · 2019: 18 · 2018: 26 · 2017: 23 · 2016: 22 · 2015: 7
- FWCI
- 7.92
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- www.springer.com/tdm (tdm)
- Locations
- The AAPS Journal (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Bristol-Myers Squibb
- Eli Lilly and Company
- Pfizer
- GlaxoSmithKline
- Biogen
- Genentech
- Novartis Institutes for BioMedical Research
- Topics
- Life Sciences › Immunology and Microbiology › Immunology › Biosimilars and Bioanalytical Methods
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Methods in Pharmaceuticals
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Keywords
- method validation, surrogate peptides, proteolytic digestion, sample preparation, method development, reference materials, internal standard, regulatory harmonization
- MeSH terms
- Animals, Canada, Chromatography, Liquid, Humans, Proteins, United States, Tandem Mass Spectrometry, Validation Studies as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review