The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Zeolitic Imidazolate Framework-Based Electrochemical Biosensor for in Vivo Electrochemical Measurements
Abstract
This study demonstrates the first exploitation of zeolitic imidazolate frameworks (ZIFs) as the matrix for constructing integrated dehydrogenase-based electrochemical biosensors for in vivo measurement of neurochemicals, such as glucose. In this study, we find that ZIFs are able to serve as a matrix for coimmobilizing electrocatalysts (i.e., methylene green, MG) and dehydrogenases (i.e., glucose dehydrogenase, GDH) onto the electrode surface and an integrated electrochemical biosensor is readily formed. We synthesize a series of ZIFs, including ZIF-7, ZIF-8, ZIF-67, ZIF-68, and ZIF-70 with different pore sizes, surface areas, and functional groups. The adsorption capabilities toward MG and GDH of these ZIFs are systematically studied with UV-vis spectroscopy, confocal laser scanning microscopy, and Fourier transfer-infrared spectroscopy. Among all the ZIFs demonstrated here, ZIF-70 shows excellent adsorption capacities toward both MG and GDH and is thus employed as the matrix for our glucose biosensor. To construct the biosensor, we first drop-coat a MG/ZIF-70 composite onto a glassy carbon electrode and then coat GDH onto the MG/ZIF-70 composite. In a continuous-flow system, the as-prepared ZIF-based biosensor is very sensitive to glucose with a linear range of 0.1-2 mM. Moreover, the ZIF-based biosensor is more highly selective on glucose than on other endogenous electroactive species in the cerebral system. In the end, we demonstrate that our biosensor is capable of monitoring dialysate glucose collected from the brain of guinea pigs selectively and in a near real-time pattern.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Electrochemical Glucose Sensors and Their Applications in Diabetes Management
Heller, A., & Feldman, B. (2008) · Chemical Reviews · doi:10.1021/cr068069y · Cited by 1,707
Biocompatible Materials for Continuous Glucose Monitoring Devices
Nichols, S. P., Koh, A., Storm, W. L., Shin, J. H., & Schoenfisch, M. H. (2013) · Chemical Reviews · doi:10.1021/cr300387j · Cited by 347
Cited by
Incorporation of biomolecules in Metal-Organic Frameworks for advanced applications
An, H., Li, M., Gao, J., Zhang, Z., Ma, S., & Chen, Y. (2019) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2019.01.001 · Cited by 336
Employing Conductive Metal–Organic Frameworks for Voltammetric Detection of Neurochemicals
Ko, M., Mendecki, L., Eagleton, A. M., Durbin, C. G., Stolz, R. M., Meng, Z., & Mirica, K. A. (2020) · Journal of the American Chemical Society · doi:10.1021/jacs.9b13402 · Cited by 298
Metadata
- Authors
- Ma, W., Jiang, Q., Yu, P., Yang, L., & Mao, L.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-07-15
- Volume
- 85
- Issue
- 15
- Pages
- 7550-7557
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2330485671
- Cited by
- 306
- References
- 3
- FWCI
- 7.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Zeolitic Imidazolate Framework-Based Electrochemical Biosensor for in Vivo Electrochemical Measurements. https://app.cochat.ai/papers/10.1021/ac401576u
- The paper
- Ma, W., Jiang, Q., Yu, P., Yang, L., & Mao, L. (2013). Zeolitic Imidazolate Framework-Based Electrochemical Biosensor for in Vivo Electrochemical Measurements. Analytical Chemistry. https://doi.org/10.1021/ac401576u
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.