Extending the Isotopically Resolved Mass Range of Orbitrap Mass Spectrometers
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
The routine analysis of large biomolecules (greater than 30 kDa) has been a challenge for Orbitrap mass spectrometers due to the relatively high kinetic energy of ions entering and within the Orbitrap mass analyzer. This characteristic results in rapid signal decay for large biomolecules due to energetic collisions with background gas molecules. Here, we report a method to significantly enhance the analysis of large biomolecules in an Orbitrap mass spectrometer. The combination of reduced C-trap and higher energy collisional dissociation (HCD) cell bath gas pressures, using helium as the bath gas and trapping ions in the HCD cell prior to mass analysis, greatly increased sensitivity and reduced signal decay for large protein ions. As a result, isotopic resolution of monoclonal immunoglobulin G was achieved, and we have established a new high-mass record for which accurate mass measurement and isotopic resolution have been achieved.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Work by the Brodbelt and Kelleher group in tuning the Orbitrap instrument parameters has increased its scope for targeted and global analysis of larger proteoforms [98,102].”
From Top-down proteomics: challenges, innovations, and applications in basic and clinical research (2020) · cites this paper as [102]
Citations
Cites
Olsen, J. V., de Godoy, L. M. F., Li, G., Macek, B., Mortensen, P., Pesch, R., Makarov, A., Lange, O., Horning, S., & Mann, M. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.t500030-mcp200 · Cited by 1,510
Electrostatic Axially Harmonic Orbital Trapping: A High-Performance Technique of Mass Analysis
Makarov, A. (2000) · Analytical Chemistry · doi:10.1021/ac991131p · Cited by 1,009
Higher-energy C-trap dissociation for peptide modification analysis
Olsen, J. V., Macek, B., Lange, O., Makarov, A., Horning, S., & Mann, M. (2007) · Nature Methods · doi:10.1038/nmeth1060 · Cited by 999
Michalski, A., Damoc, E., Hauschild, J.-P., Lange, O., Wieghaus, A., Makarov, A., Nagaraj, N., Cox, J., Mann, M., & Horning, S. (2011) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m111.011015 · Cited by 832
Performance Evaluation of a Hybrid Linear Ion Trap/Orbitrap Mass Spectrometer
Makarov, A., Denisov, E., Kholomeev, A., Balschun, W., Lange, O., Strupat, K., & Horning, S. (2006) · Analytical Chemistry · doi:10.1021/ac0518811 · Cited by 777
Proceedings of the 46th ASMS Conference on Mass Spectrometry and Allied Topics
Bruins, A. P. (1998) · Cited by 642
Orbitrap mass spectrometry: Instrumentation, ion motion and applications
Perry, R. H., Cooks, R. G., & Noll, R. J. (2008) · Mass Spectrometry Reviews · doi:10.1002/mas.20186 · Cited by 514
Dynamic range of mass accuracy in LTQ orbitrap hybrid mass spectrometer
Makarov, A., Denisov, E., Lange, O., & Horning, S. (2006) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2006.03.006 · Cited by 431
High-Resolution Mass Spectrometers
Marshall, A. G., & Hendrickson, C. L. (2008) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.112945 · Cited by 394
High-sensitivity Orbitrap mass analysis of intact macromolecular assemblies
Rose, R. J., Damoc, E., Denisov, E., Makarov, A., & Heck, A. J. R. (2012) · Nature Methods · doi:10.1038/nmeth.2208 · Cited by 392
Research works printed but not linked: 1
- Denisov E., 2012, Proceedings of the 60th ASMS Conference on Mass Spectrometry and Allied Topics
Cited by
Zhang, Z., Wu, S., Stenoien, D. L., & Paša-Tolić, L. (2014) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071213-020216 · Cited by 323
Protein–Small Molecule Interactions in Native Mass Spectrometry
Bennett, J. L., Nguyen, G. T. H., & Donald, W. A. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00293 · Cited by 168
Top-down proteomics: challenges, innovations, and applications in basic and clinical research
Brown, K. A., Melby, J. A., Roberts, D. S., & Ge, Y. (2020) · Expert Review of Proteomics · doi:10.1080/14789450.2020.1855982 · Cited by 152
Boundaries of Mass Resolution in Native Mass Spectrometry
Lössl, P., Snijder, J., & Heck, A. J. R. (2014) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-014-0874-3 · Cited by 162
Srzentić, K., Fornelli, L., Tsybin, Y. O., Loo, J. A., Seckler, H. S., Agar, J. N., Anderson, L. C., Bai, D. L., Beck, A., Brodbelt, J. S., et al. (2020) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.0c00036 · Cited by 131
Self-citation
Metadata
- Authors
- Shaw, J. B., & Brodbelt, J. S.
- Affiliations
- The University of Texas at Austin (US)
- Corresponding author
- Brodbelt, Jennifer S.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-08-15
- Volume
- 85
- Issue
- 17
- Pages
- 8313-8318
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2039710652
- Cited by
- 28
- References
- 22
- Citations by year
- 2025: 1 · 2024: 2 · 2022: 1 · 2021: 3 · 2020: 4 · 2019: 3 · 2018: 5 · 2017: 2 · 2016: 1 · 2015: 2 · 2014: 3
- FWCI
- 0.90
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Metabolomics and Mass Spectrometry Studies
- Keywords
- Orbitrap mass spectrometer, large biomolecules, ion kinetic energy, signal decay, higher-energy collisional dissociation, protein ions, monoclonal immunoglobulin G, isotopic resolution, accurate mass measurement
- MeSH terms
- Animals, Cattle, Chromatography, Liquid, Horses, Myoglobin, Serum Albumin, Bovine, Mass Spectrometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Extending the Isotopically Resolved Mass Range of Orbitrap Mass Spectrometers. https://app.cochat.ai/papers/10.1021/ac401634b
- The paper
- Shaw, J. B., & Brodbelt, J. S. (2013). Extending the Isotopically Resolved Mass Range of Orbitrap Mass Spectrometers. Analytical Chemistry. https://doi.org/10.1021/ac401634b
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.