CoChat

Measurement of Individual Ions Sharply Increases the Resolution of Orbitrap Mass Spectra of Proteins

The DOI matches its Crossref record; 32 of the 33 references it cites were found in a registry or an index.

Abstract

It is well-known that with Orbitrap-based Fourier-transform-mass-spectrometry (FT-MS) analysis, longer-time-domain signals are needed to better resolve species of interest. Unfortunately, increasing the signal-acquisition period comes at the expense of increasing ion decay, which lowers signal-to-noise ratios and ultimately limits resolution. This is especially problematic for intact proteins, including antibodies, which demonstrate rapid decay because of their larger collisional cross-sections, and result in more frequent collisions with background gas molecules. Provided here is a method that utilizes numerous low-ion-count spectra and single-ion processing to reconstruct a conventional m/ z spectrum. This technique has been applied to proteins varying in molecular weight from 8 to 150 kDa, with a resolving power of 677 000 achieved for transients of carbonic anhydrase (29 kDa) with a duration of only ∼250 ms. A resolution improvement ranging from 10- to 20-fold was observed for all proteins, providing isotopic resolution where none was previously present.

Overview

Integrity signals

Registry

Crossref · 10.1021/acs.analchem.8b04519

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 32 references

Research works printed but not linked: 1

  1. Campuzano I. D. G., 2015, State-of-the-Art and Emerging Technologies for Therapeutic Monoclonal Antibody Characterization Vol. 3. Defining the Next Generation of Analytical and Biophysical Techniques, 1202, 75

Cited by

See all 87

Metadata

Authors
Kafader, J. O., Melani, R. D., Senko, M. W., Makarov, A. A., Kelleher, N. L., & Compton, P. D.
Affiliations
  • Northwestern University (US)
  • Thermo Fisher Scientific (United States) (US)
  • Thermo Fisher Scientific (Germany) (DE)
Corresponding author
Compton, Philip D.
Venue
Analytical Chemistry
Published
2019-01-04
Volume
91
Issue
4
Pages
2776-2783
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2908399125
Cited by
87
References
33
Citations by year
2026: 9 · 2025: 11 · 2024: 11 · 2023: 15 · 2022: 12 · 2021: 14 · 2020: 10 · 2019: 5
FWCI
4.09
Type
journal article
Language
en
Open access
closed
Locations
  • Analytical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
Funders
Thermo Fisher Scientific
Topics
  • Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
  • Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Metabolomics and Mass Spectrometry Studies
Keywords
Orbitrap mass spectrometry, protein mass spectrometry, spectral resolution enhancement, signal-to-noise ratio, carbonic anhydrase, isotopic resolution, Fourier transform mass spectrometry
MeSH terms
Animals, Carbonic Anhydrases, Fourier Analysis, Humans, Ions, Myoglobin, Phosphopyruvate Hydratase, Proteins, Mass Spectrometry, Transferrin, Ubiquitin

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Measurement of Individual Ions Sharply Increases the Resolution of Orbitrap Mass Spectra of Proteins. https://app.cochat.ai/papers/10.1021/acs.analchem.8b04519
The paper
Kafader, J. O., Melani, R. D., Senko, M. W., Makarov, A. A., Kelleher, N. L., & Compton, P. D. (2019). Measurement of Individual Ions Sharply Increases the Resolution of Orbitrap Mass Spectra of Proteins. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.8b04519

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.