Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 235

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

High Specific and Ultrasensitive Isothermal Detection of MicroRNA by Padlock Probe-Based Exponential Rolling Circle Amplification

Liu, Haiyun, Li, Lu, Duan, Lili, Wang, Xu, Xie, Yanxia, Tong, Lili, Wang, Qian, Tang, Bo·2013·Analytical Chemistry

Abstract

In this paper, a padlock probe-based exponential rolling circle amplification (P-ERCA) assay is developed for highly specific and sensitive detection of microRNA (miRNA). The padlock probe is composed of a hybridization sequence to miRNA and a nicking site for nicking endonuclease. Using the miRNA as a template, specific ligation to the padlock probe and linear rolling circle reaction (LRCA) are achieved under isothermal conditions. After multiple nicking reactions, many copies of short DNA products are successively produced and then used as triggers in next circle amplification. Thus, a small amount of miRNAs are converted to a large number of triggers to initiate the rolling circle amplification reaction, and circular exponential signal amplification is achieved. This padlock probe-based exponential rolling circle amplification assay exhibits a remarkable sensitivity of 0.24 zmol using optimized sequences of the padlock probe. The target-dependent circularization of the padlock probe and the ligation reaction could improve the specificity effectively, leading to single-nucleotide difference discrimination between miRNA family members. The miRNA analysis in human lung cells was performed with this method. The result indicates this highly sensitive P-ERCA strategy will become a promising miRNA quantification method in early clinical diagnostics.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac401715k

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 235

Metadata

Authors
Liu, H., Li, L., Duan, L., Wang, X., Xie, Y., Tong, L., Wang, Q., & Tang, B.
Venue
Analytical Chemistry
Published
2013-07-31
Volume
85
Issue
16
Pages
7941-7947
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2125565427
Cited by
235
References
1
FWCI
10.22
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High Specific and Ultrasensitive Isothermal Detection of MicroRNA by Padlock Probe-Based Exponential Rolling Circle Amplification. https://app.cochat.ai/papers/10.1021/ac401715k
The paper
Liu, H., Li, L., Duan, L., Wang, X., Xie, Y., Tong, L., Wang, Q., & Tang, B. (2013). High Specific and Ultrasensitive Isothermal Detection of MicroRNA by Padlock Probe-Based Exponential Rolling Circle Amplification. Analytical Chemistry. https://doi.org/10.1021/ac401715k

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.