Capillary Electrophoresis/Mass Spectrometry of APTS-Labeled Glycans for the Identification of Unknown Glycan Species in Capillary Electrophoresis/Laser-Induced Fluorescence Systems
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
The examination of protein glycosylation is of high importance, especially in the (bio)pharmaceutical sector. The analysis of protein glycosylation is conducted routinely in high performance by capillary electrophoresis with laser-induced fluorescence (CE/LIF) using 8-aminopyrene-1,3,6-trisulfonic acid (APTS)-labeled glycans. In this work we present an optimized capillary electrophoresis/time-of-flight mass spectrometry (CE/TOF-MS) methodology for these labeled glycans, which combines the high separation performance of CE with the high resolution, accuracy, and speed of TOF-MS for eased glycan identification. The system based on an acidic background electrolyte (BGE) provides a migration direction analogue to routine CE/LIF systems. Different BGE compositions, capillary dimensions, coatings, and instrumental parameters were tested to optimize the system with respect to separation efficiency and robustness. Subsequently, the CE/MS method optimized for acidic conditions was compared to an alkaline CE/MS method. Further, the mobilities of six APTS-labeled complex-type N-glycans were compared for both CE/MS methods and two standard CE/LIF approaches. For the acidic and alkaline BGE systems, the mobilities of sialylated glycans were shifted relative to nonsialylated glycans in comparison to common CE/LIF systems. However, in this study a straightforward unequivocal peak assignment was achieved for all unknown glycans in a medium complex glycan mixture from a fusion protein.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Glycosylation as a strategy to improve antibody-based therapeutics
Jefferis, R. (2009) · Nature Reviews Drug Discovery · doi:10.1038/nrd2804 · Cited by 829
Huhn, C., Selman, M. H. J., Ruhaak, L. R., Deelder, A. M., & Wuhrer, M. (2009) · PROTEOMICS · doi:10.1002/pmic.200800715 · Cited by 301
New Technologies for Glycomic Analysis: Toward a Systematic Understanding of the Glycome
Rakus, J. F., & Mahal, L. K. (2011) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-061010-113951 · Cited by 117
HILIC analysis of fluorescence-labeled N-glycans from recombinant biopharmaceuticals
Melmer, M., Stangler, T., Schiefermeier, M., Brunner, W., Toll, H., Rupprechter, A., Lindner, W., & Premstaller, A. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3988-x · Cited by 104
Analysis of glycans derived from glycoconjugates by capillary electrophoresis‐mass spectrometry
Mechref, Y. (2011) · ELECTROPHORESIS · doi:10.1002/elps.201100342 · Cited by 64
Cited by
Fekete, S., Guillarme, D., Sandra, P., & Sandra, K. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b04561 · Cited by 258
Reusch, D., Haberger, M., Maier, B., Maier, M., Kloseck, R., Zimmermann, B., Hook, M., Szabo, Z., Tep, S., Wegstein, J., et al. (2015) · mAbs · doi:10.4161/19420862.2014.986000 · Cited by 168
Zhong, X., Chen, Z., Snovida, S., Liu, Y., Rogers, J. C., & Li, L. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b01835 · Cited by 92
Váradi, C., Mittermayr, S., Millán-Martín, S., & Bones, J. (2016) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-016-9935-8 · Cited by 40
Recent advances of capillary electrophoresis-mass spectrometry instrumentation and methodology
Jiang, Y., He, M.-Y., Zhang, W.-J., Luo, P., Guo, D., Fang, X., & Xu, W. (2017) · Chinese Chemical Letters · doi:10.1016/j.cclet.2017.05.008 · Cited by 30
Metadata
- Authors
- Bunz, S.-C., Rapp, E., & Neusüss, C.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-10-15
- Volume
- 85
- Issue
- 21
- Pages
- 10218-10224
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2068031049
- Cited by
- 78
- References
- 5
- FWCI
- 2.56
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Capillary Electrophoresis/Mass Spectrometry of APTS-Labeled Glycans for the Identification of Unknown Glycan Species in Capillary Electrophoresis/Laser-Induced Fluorescence Systems. https://app.cochat.ai/papers/10.1021/ac401930j
- The paper
- Bunz, S.-C., Rapp, E., & Neusüss, C. (2013). Capillary Electrophoresis/Mass Spectrometry of APTS-Labeled Glycans for the Identification of Unknown Glycan Species in Capillary Electrophoresis/Laser-Induced Fluorescence Systems. Analytical Chemistry. https://doi.org/10.1021/ac401930j
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.