The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Comparison of Information-Dependent Acquisition, SWATH, and MSAll Techniques in Metabolite Identification Study Employing Ultrahigh-Performance Liquid Chromatography–Quadrupole Time-of-Flight Mass Spectrometry
Abstract
Sensitive and selective liquid chromatography-mass spectrometry (LC-MS) analysis is a powerful and essential tool for metabolite identification in drug discovery and development. An MS(2) (or tandem, MS/MS) mass spectrum is acquired from the fragmentation of a precursor ion by multiple methods including information-dependent acquisition (IDA), SWATH (sequential window acquisition of all theoretical fragment-ion spectra), and MS(All) (also called MS(E)) techniques. We compared these three techniques in their capabilities to produce comprehensive MS(2) data by assessing both metabolite MS(2) acquisition hit rate and the quality of MS(2) spectra. Rat liver microsomal incubations from eight test compounds were analyzed with four methods (IDA, MMDF (multiple mass defect filters)-IDA, SWATH, or MS(All)) using an ultrahigh-performance liquid chromatography-qudrupole time-of-flight mass spectrometry (UHPLC-Q-TOF MS) platform. A combined total of 227 drug-related materials (DRM) were detected from all eight test article incubations, and among those, 5% and 4% of DRM were not triggered for MS(2) acquisition with IDA and MMDF-IDA methods, respectively. When the same samples were spiked to an equal volume of blank rat urine (urine sample), the DRM without MS(2) acquisition increased to 29% and 18%, correspondingly. In contrast, 100% of DRM in both matrixes were subjected to MS(2) acquisition with either the SWATH or MS(All) method. However, the quality of the acquired MS(2) spectra decreased in the order of IDA, SWATH, and MS(All) methods. An average of 10, 9, and 6 out of 10 most abundant ions in MS(2) spectra were the real product ions of DRM detected in microsomal samples from IDA, SWATH, and MS(All) methods, respectively. The corresponding numbers declined to 9, 6, and 3 in the urine samples. Overall, IDA-based methods acquired qualitatively better MS(2) spectra but with a lower MS(2) acquisition hit rate than the other two methods. SWATH outperformed the MS(All) method given its better quality of MS(2) spectra with an identical MS(2) acquisition hit rate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gillet, L. C., Navarro, P., Tate, S., Röst, H., Selevsek, N., Reiter, L., Bonner, R., & Aebersold, R. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o111.016717 · Cited by 2,877
Cited by
MS-DIAL: data-independent MS/MS deconvolution for comprehensive metabolome analysis
Tsugawa, H., Cajka, T., Kind, T., Ma, Y., Higgins, B., Ikeda, K., Kanazawa, M., VanderGheynst, J., Fiehn, O., & Arita, M. (2015) · Nature Methods · doi:10.1038/nmeth.3393 · Cited by 3,397
Cajka, T., & Fiehn, O. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b04491 · Cited by 830
Challenges, progress and promises of metabolite annotation for LC–MS-based metabolomics
Chaleckis, R., Meister, I., Zhang, P., & Wheelock, C. E. (2019) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2018.07.010 · Cited by 368
Guo, J., & Huan, T. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b05135 · Cited by 312
Genome-wide pQTL analysis of protein expression regulatory networks in the human liver
He, B., Shi, J., Wang, X., Jiang, H., & Zhu, H.-J. (2020) · BMC Biology · doi:10.1186/s12915-020-00830-3 · Cited by 72
Metadata
- Authors
- Zhu, X., Chen, Y., & Subramanian, R.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-01-02
- Volume
- 86
- Issue
- 2
- Pages
- 1202-1209
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2060780778
- Cited by
- 213
- References
- 1
- FWCI
- 5.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of Information-Dependent Acquisition, SWATH, and MSAll Techniques in Metabolite Identification Study Employing Ultrahigh-Performance Liquid Chromatography–Quadrupole Time-of-Flight Mass Spectrometry. https://app.cochat.ai/papers/10.1021/ac403385y
- The paper
- Zhu, X., Chen, Y., & Subramanian, R. (2014). Comparison of Information-Dependent Acquisition, SWATH, and MSAll Techniques in Metabolite Identification Study Employing Ultrahigh-Performance Liquid Chromatography–Quadrupole Time-of-Flight Mass Spectrometry. Analytical Chemistry. https://doi.org/10.1021/ac403385y
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.