The DOI matches its Crossref record.
Ratiometric Fluorescence Probe for Monitoring Hydroxyl Radical in Live Cells Based on Gold Nanoclusters
Abstract
Determination of hydroxyl radical ((•)OH) with high sensitivity and accuracy in live cells is a challenge for evaluating the role that (•)OH plays in the physiological and pathological processes. In this work, a ratiometric fluorescence biosensor for (•)OH was developed, in which gold nanocluster (AuNC) protected by bovine serum albumin was employed as a reference fluorophore and the organic molecule 2-[6-(4'-hydroxy)phenoxy-3H-xanthen-3-on-9-yl]benzoic acid (HPF) acted as both the response signal and specific recognition element for (•)OH. In the absence of (•)OH, only one emission peak at 637 nm ascribed to AuNCs was observed, because HPF was almost nonfluorescent. However, fluorescence emission at 515 nm attributed to the HPF product after reaction with (•)OH--dianionic fluorescein--gradually increased with the continuous addition of (•)OH, while the emission at 637 nm stays constant, resulting in a ratiometric determination of (•)OH. The developed fluorescent sensor exhibited high selectivity for (•)OH over other reactive oxygen species (ROS), reactive nitrogen species (RNS), metal ions, and other biological species, as well as high accuracy and sensitivity with low detection limit to ∼0.68 μM, which fulfills the requirements for detection of (•)OH in a biological system. In addition, the AuNC-based inorganic-organic probe showed long-term stability against light illumination and pH, good cell permeability, and low cytotoxicity. As a result, the present ratiometric sensor was successfully used for bioimaging and monitoring of (•)OH changes in live cells upon oxidative stress.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Chen, X., Wang, F., Hyun, J. Y., Wei, T., Qiang, J., Ren, X., Shin, I., & Yoon, J. (2016) · Chem. Soc. Rev. · doi:10.1039/c6cs00192k · Cited by 1,166
Fluorescent Gold Nanoclusters: Recent Advances in Sensing and Imaging
Chen, L.-Y., Wang, C.-W., Yuan, Z., & Chang, H.-T. (2015) · Analytical Chemistry · doi:10.1021/ac503636j · Cited by 848
Ratiometric optical nanoprobes enable accurate molecular detection and imaging
Huang, X., Song, J., Yung, B. C., Huang, X., Xiong, Y., & Chen, X. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00612h · Cited by 820
Metal nanoclusters: novel probes for diagnostic and therapeutic applications
Tao, Y., Li, M., Ren, J., & Qu, X. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00607d · Cited by 736
Kwon, N., Kim, D., Swamy, K. M. K., & Yoon, J. (2021) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2020.213581 · Cited by 301
Metadata
- Authors
- Zhuang, M., Ding, C., Zhu, A., & Tian, Y.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-01-14
- Volume
- 86
- Issue
- 3
- Pages
- 1829-1836
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2322336736
- Cited by
- 229
- References
- 0
- FWCI
- 11.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ratiometric Fluorescence Probe for Monitoring Hydroxyl Radical in Live Cells Based on Gold Nanoclusters. https://app.cochat.ai/papers/10.1021/ac403810g
- The paper
- Zhuang, M., Ding, C., Zhu, A., & Tian, Y. (2014). Ratiometric Fluorescence Probe for Monitoring Hydroxyl Radical in Live Cells Based on Gold Nanoclusters. Analytical Chemistry. https://doi.org/10.1021/ac403810g
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.