Hydrogel Micropatches for Sampling and Profiling Skin Metabolites
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Metabolites excreted by skin have a huge potential as disease biomarkers. However, due to the shortage of convenient sampling/analysis methods, the analysis of sweat has not become very popular in the clinical setting (pilocarpine iontophoresis being a prominent exception). In this report, a facile method for sampling and rapid chemical profiling of skin metabolites excreted with sweat is proposed. Metabolites released by skin (primarily the constituents of sweat) are collected into hydrogel (agarose) micropatches. Subsequently, they are extracted in an online analytical setup incorporating nanospray desorption electrospray ionization and an ion trap mass spectrometer. In a series of reference measurements, using bulk sampling and electrospray ionization mass spectrometry, various low-molecular-weight metabolites are detected in the micropatches exposed to skin. The sampling time is as short as 10 min, while the desorption time is 2 min. Technical precision of micropatch analysis varies within the range of 3-42%, depending on the sample and the method of data treatment; the best technical precision (≤10%) has been achieved while using an isotopically labeled internal standard. The limits of detection range from 7 to 278 pmol. Differences in the quantities of extracted metabolites are observed for the samples obtained from healthy individuals (intersubject variabilities: 30-89%; n = 9), which suggests that this method may have the potential to become a semiquantitative assay in clinical analysis and forensics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Textural properties of agarose gels. I. Rheological and fracture properties
Barrangou, L. M., Daubert, C. R., & Allen Foegeding, E. (2006) · Food Hydrocolloids · doi:10.1016/j.foodhyd.2005.02.019 · Cited by 145
Mark, H., & Harding, C. R. (2013) · International Journal of Cosmetic Science · doi:10.1111/ics.12019 · Cited by 75
Nicotine monitoring in sweat with a sweat patch
Kintz, P., Henrich, A., Cirimele, V., & Ludes, B. (1998) · Journal of Chromatography B: Biomedical Sciences and Applications · doi:10.1016/s0378-4347(97)00551-3 · Cited by 57
Cited by
Multifunctional conductive hydrogel-based flexible wearable sensors
Wang, L., Xu, T., & Zhang, X. (2021) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2020.116130 · Cited by 507
Lin, S., Wang, B., Zhao, Y., Shih, R., Cheng, X., Yu, W., Hojaiji, H., Lin, H., Hoffman, C., Ly, D., et al. (2020) · ACS Sensors · doi:10.1021/acssensors.9b01727 · Cited by 114
Finger sweat analysis enables short interval metabolic biomonitoring in humans
Brunmair, J., Gotsmy, M., Niederstaetter, L., Neuditschko, B., Bileck, A., Slany, A., Feuerstein, M. L., Langbauer, C., Janker, L., Zanghellini, J., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-26245-4 · Cited by 96
(2017) · PubMed Central · Cited by 76
Harshman, S. W., Pitsch, R. L., Smith, Z. K., O’Connor, M. L., Geier, B. A., Qualley, A. V., Schaeublin, N. M., Fischer, M. V., Eckerle, J. J., Strang, A. J., et al. (2018) · PLOS ONE · doi:10.1371/journal.pone.0203133 · Cited by 51
Metadata
- Authors
- Dutkiewicz, E. P., Lin, J.-D., Tseng, T.-W., Wang, Y.-S., & Urban, P. L.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-02-21
- Volume
- 86
- Issue
- 5
- Pages
- 2337-2344
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2012006094
- Cited by
- 77
- References
- 3
- FWCI
- 2.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.