The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Sensitive Electrochemical Aptamer Biosensor for Dynamic Cell Surface N-Glycan Evaluation Featuring Multivalent Recognition and Signal Amplification on a Dendrimer–Graphene Electrode Interface
Open accessAbstract
We demonstrate a multivalent recognition and highly selective aptamer signal amplification strategy for electrochemical cytosensing and dynamic cell surface N-glycan expression evaluation by the combination of concanavalin A (Con A), a mannose binding protein, as a model, conjugated poly(amidoamine) dendrimer on a chemically reduced graphene oxide (rGO-DEN) interface, and aptamer- and horseradish peroxidase-modified gold nanoparticles (HRP-aptamer-AuNPs) as nanoprobes. In this strategy, the rGO-DEN can not only enhance the electron transfer ability but also provide a multivalent recognition interface for the conjugation of Con A that avoids the weak carbohydrate-protein interaction and dramatically improves the cell capture efficiency and the sensitivity of the biosensor for cell surface glycan. The high-affinity aptamer- and HRP-modified gold nanoparticles provide an ultrasensitive electrochemical probe with excellent specificity. As proof-of-concept, the detection of CCRF-CEM cell (human acute lymphoblastic leukemia) and its surface N-glycan was developed. It has demonstrated that the as-designed biosensor can be used for highly sensitive and selective cell detection and dynamic evaluation of cell surface N-glycan expression. A detection limit as low as 10 cells mL(-1) was obtained with excellent selectivity. Moreover, this strategy was also successfully applied for N-glycan expression inhibitor screening. These results imply that this biosensor has potential in clinical diagnostic and drug screening applications and endows a feasibility tool for insight into the N-glycan function in biological processes and related diseases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Role of Glycosylation in Development
Haltiwanger, R. S., & Lowe, J. B. (2004) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.73.011303.074043 · Cited by 757
Metabolism, Cell Surface Organization, and Disease
Dennis, J. W., Nabi, I. R., & Demetriou, M. (2009) · Cell · doi:10.1016/j.cell.2009.12.008 · Cited by 450
N-Glycans in cancer progression
Lau, K. S., & Dennis, J. W. (2008) · Glycobiology · doi:10.1093/glycob/cwn071 · Cited by 390
Glycomic analysis by capillary electrophoresis–mass spectrometry
Mechref, Y., & Novotny, M. V. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20196 · Cited by 105
Cited by
Electrochemical Sensors and Biosensors Based on Nanomaterials and Nanostructures
Zhu, C., Yang, G., Li, H., Du, D., & Lin, Y. (2015) · Analytical Chemistry · doi:10.1021/ac5039863 · Cited by 1,741
Electrochemical Biosensors in Point‐of‐Care Devices: Recent Advances and Future Trends
da Silva, E. T. S. G., Souto, D. E. P., Barragan, J. T. C., de F. Giarola, J., de Moraes, A. C. M., & Kubota, L. T. (2017) · ChemElectroChem · doi:10.1002/celc.201600758 · Cited by 373
Zhang, H., Wang, Z., Zhang, Q., Wang, F., & Liu, Y. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.10.016 · Cited by 331
Self-citationZhang, W., Zhu, S., Luque, R., Han, S., Hu, L., & Xu, G. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00297d · Cited by 313
Opportunities and challenges of real-time release testing in biopharmaceutical manufacturing
Jiang, M., Severson, K. A., Love, J. C., Madden, H., Swann, P., Zang, L., & Braatz, R. D. (2017) · Biotechnology and Bioengineering · doi:10.1002/bit.26383 · Cited by 118
Metadata
- Authors
- Chen, X., Wang, Y., Zhang, Y., Chen, Z., Liu, Y., Li, Z., & Li, J.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-04-16
- Volume
- 86
- Issue
- 9
- Pages
- 4278-4286
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2328176321
- Cited by
- 171
- References
- 4
- FWCI
- 8.15
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.