The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Electrokinetic Preconcentration and Detection of Neuropeptides at Patterned Graphene-Modified Electrodes in a Nanochannel
Abstract
Neuropeptides are vital to the transmission and modulation of neurological signals, with Neuropeptide Y (NPY) and Orexin A (OXA) offering diagnostic information on stress, depression, and neurotrauma. NPY is an especially significant biomarker, since it can be noninvasively collected from sweat, but its detection has been limited by poor sensitivity, long assay times, and the inability to scale-down sample volumes. Herein, we apply electrokinetic preconcentration of the neuropeptide onto patterned graphene-modified electrodes in a nanochannel by frequency-selective dielectrophoresis for 10 s or by electrochemical adsorptive accumulation for 300 s, to enable the electrochemical detection of NPY and OXA at picomolar levels from subnanoliter samples, with sufficient signal sensitivity to avoid interferences from high levels of dopamine and ascorbic acid within biological matrices. Given the high sensitivity of the methodology within small volume samples, we envision its utility toward off-line detection from droplets collected by microdialysis for the eventual measurement of neuropeptides at high spatial and temporal resolutions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cizza, G., Marques, A. H., Eskandari, F., Christie, I. C., Torvik, S., Silverman, M. N., Phillips, T. M., & Sternberg, E. M. (2008) · Biological Psychiatry · doi:10.1016/j.biopsych.2008.05.035 · Cited by 208
Heilig, M., Zachrisson, O., Thorsell, A., Ehnvall, A., Mottagui-Tabar, S., Sjögren, M., Åsberg, M., Ekman, R., Wahlestedt, C., & Ågren, H. (2004) · Journal of Psychiatric Research · doi:10.1016/s0022-3956(03)00101-8 · Cited by 177
Cited by
Technology Roadmap for Flexible Sensors
Luo, Y., Abidian, M. R., Ahn, J.-H., Akinwande, D., Andrews, A. M., Antonietti, M., Bao, Z., Berggren, M., Berkey, C. A., Bettinger, C. J., et al. (2023) · ACS Nano · doi:10.1021/acsnano.2c12606 · Cited by 1,383
Asfaram, A., Ghaedi, M., Agarwal, S., Tyagi, I., & Kumar Gupta, V. (2015) · RSC Advances · doi:10.1039/c4ra15637d · Cited by 726
Skin-Interfaced Wearable Sweat Sensors for Precision Medicine
Min, J., Tu, J., Xu, C., Lukas, H., Shin, S., Yang, Y., Solomon, S. A., Mukasa, D., & Gao, W. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00823 · Cited by 712
Nanomaterial-based electrochemical sensing of neurological drugs and neurotransmitters
Sanghavi, B. J., Wolfbeis, O. S., Hirsch, T., & Swami, N. S. (2015) · Microchimica Acta · doi:10.1007/s00604-014-1308-4 · Cited by 328
Self-citationStress Biomarkers in Biological Fluids and Their Point-of-Use Detection
Steckl, A. J., & Ray, P. (2018) · ACS Sensors · doi:10.1021/acssensors.8b00726 · Cited by 319
Li, Y., Zhong, Y., Zhang, Y., Weng, W., & Li, S. (2015) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2014.09.016 · Cited by 285
Adsorptive removal of cadmium(II) ions from liquid phase using acid modified carbon-based adsorbents
Ihsanullah, Al-Khaldi, F. A., Abusharkh, B., Khaled, M., Atieh, M. A., Nasser, M. S., laoui, T., Saleh, T. A., Agarwal, S., Tyagi, I., et al. (2015) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2015.01.033 · Cited by 263
Frkonja-Kuczin, A., Ray, L., Zhao, Z., Konopka, M. C., & Boika, A. (2018) · Electrochimica Acta · doi:10.1016/j.electacta.2018.05.120 · Cited by 24
Metadata
- Authors
- Sanghavi, B. J., Varhue, W., Chávez, J. L., Chou, C.-F., & Swami, N. S.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-04-08
- Volume
- 86
- Issue
- 9
- Pages
- 4120-4125
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2327420577
- Cited by
- 195
- References
- 2
- FWCI
- 19.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.