The DOI matches its Crossref record.
High Resolution Trapped Ion Mobility Spectrometery of Peptides
Abstract
In the present work, we employ trapped ion mobility spectrometry (TIMS) for conformational analysis of several model peptides. The TIMS distributions are extensively compared to recent ion mobility spectrometry (IMS) studies reported in the literature. At a resolving power (R) exceeding 250, many new features, otherwise hidden by lower resolution IMS analyzers, are revealed. Though still principally limited by the plurality of conformational states, at present, TIMS offers R up to ∼3 to 8 times greater than modern drift tube or traveling wave IMS techniques, respectively. Unlike differential IMS, TIMS not only is able to resolve congested conformational features but also can be used to determine information about their relative size, via the ion-neutral collision cross section, offering a powerful new platform to probe the structure and dynamics of biochemical systems in the gas phase.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Meier, F., Brunner, A.-D., Koch, S., Koch, H., Lubeck, M., Krause, M., Goedecke, N., Decker, J., Kosinski, T., Park, M. A., et al. (2018) · Molecular & Cellular Proteomics · doi:10.1074/mcp.tir118.000900 · Cited by 965
Self-citationIon Mobility Spectrometry: Fundamental Concepts, Instrumentation, Applications, and the Road Ahead
Dodds, J. N., & Baker, E. S. (2019) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-019-02288-2 · Cited by 574
Recommendations for reporting ion mobility Mass Spectrometry measurements
Gabelica, V., Shvartsburg, A. A., Afonso, C., Barran, P., Benesch, J. L. P., Bleiholder, C., Bowers, M. T., Bilbao, A., Bush, M. F., Campbell, J. L., et al. (2019) · Mass Spectrometry Reviews · doi:10.1002/mas.21585 · Cited by 493
Self-citationIon Mobility-Mass Spectrometry: Time-Dispersive Instrumentation
May, J. C., & McLean, J. A. (2015) · Analytical Chemistry · doi:10.1021/ac504720m · Cited by 435
Meier, F., Beck, S., Grassl, N., Lubeck, M., Park, M. A., Raether, O., & Mann, M. (2015) · Journal of Proteome Research · doi:10.1021/acs.jproteome.5b00932 · Cited by 423
Self-citationFundamentals of Trapped Ion Mobility Spectrometry
Michelmann, K., Silveira, J. A., Ridgeway, M. E., & Park, M. A. (2015) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-014-0999-4 · Cited by 374
Self-citationTrapped ion mobility spectrometry: A short review
Ridgeway, M. E., Lubeck, M., Jordens, J., Mann, M., & Park, M. A. (2018) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2018.01.006 · Cited by 308
Self-citationRecent technological developments for native mass spectrometry
Webb, I. K. (2022) · Biochimica et Biophysica Acta (BBA) - Proteins and Proteomics · doi:10.1016/j.bbapap.2021.140732 · Cited by 29
Hollerbach, A. L., Lin, V. S., Ibrahim, Y. M., Ewing, R. G., Metz, T. O., & Rodda, K. E. (2024) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.4c00200 · Cited by 18
Metadata
- Authors
- Silveira, J. A., Ridgeway, M. E., & Park, M. A.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-05-28
- Volume
- 86
- Issue
- 12
- Pages
- 5624-5627
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2004236987
- Cited by
- 196
- References
- 0
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.