The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Fundamentals of Trapped Ion Mobility Spectrometry
Abstract
Trapped ion mobility spectrometry (TIMS) is a relatively new gas-phase separation method that has been coupled to quadrupole orthogonal acceleration time-of-flight mass spectrometry. The TIMS analyzer is a segmented rf ion guide wherein ions are mobility-analyzed using an electric field that holds ions stationary against a moving gas, unlike conventional drift tube ion mobility spectrometry where the gas is stationary. Ions are initially trapped, and subsequently eluted from the TIMS analyzer over time according to their mobility (K). Though TIMS has achieved a high level of performance (R > 250) in a small device (<5 cm) using modest operating potentials (<300 V), a proper theory has yet to be produced. Here, we develop a quantitative theory for TIMS via mathematical derivation and simulations. A one-dimensional analytical model, used to predict the transit time and theoretical resolving power, is described. Theoretical trends are in agreement with experimental measurements performed as a function of K, pressure, and the axial electric field scan rate. The linear dependence of the transit time with 1/K provides a fundamental basis for determination of reduced mobility or collision cross section values by calibration. The quantitative description of TIMS provides an operational understanding of the analyzer, outlines the current performance capabilities, and provides insight into future avenues for improvement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hall, Z., Politis, A., Bush, M. F., Smith, L. J., & Robinson, C. V. (2012) · Journal of the American Chemical Society · doi:10.1021/ja2096859 · Cited by 267
Cited by
Meier, F., Brunner, A.-D., Koch, S., Koch, H., Lubeck, M., Krause, M., Goedecke, N., Decker, J., Kosinski, T., Park, M. A., et al. (2018) · Molecular & Cellular Proteomics · doi:10.1074/mcp.tir118.000900 · Cited by 965
Self-citationIon Mobility Spectrometry: Fundamental Concepts, Instrumentation, Applications, and the Road Ahead
Dodds, J. N., & Baker, E. S. (2019) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-019-02288-2 · Cited by 574
Recommendations for reporting ion mobility Mass Spectrometry measurements
Gabelica, V., Shvartsburg, A. A., Afonso, C., Barran, P., Benesch, J. L. P., Bleiholder, C., Bowers, M. T., Bilbao, A., Bush, M. F., Campbell, J. L., et al. (2019) · Mass Spectrometry Reviews · doi:10.1002/mas.21585 · Cited by 493
Self-citationMeier, F., Beck, S., Grassl, N., Lubeck, M., Park, M. A., Raether, O., & Mann, M. (2015) · Journal of Proteome Research · doi:10.1021/acs.jproteome.5b00932 · Cited by 423
Self-citationTrapped ion mobility spectrometry: A short review
Ridgeway, M. E., Lubeck, M., Jordens, J., Mann, M., & Park, M. A. (2018) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2018.01.006 · Cited by 308
Self-citation
Metadata
- Authors
- Michelmann, K., Silveira, J. A., Ridgeway, M. E., & Park, M. A.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-10-21
- Volume
- 26
- Issue
- 1
- Pages
- 14-24
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2088546850
- Cited by
- 374
- References
- 1
- FWCI
- 7.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fundamentals of Trapped Ion Mobility Spectrometry. https://app.cochat.ai/papers/10.1007/s13361-014-0999-4
- The paper
- Michelmann, K., Silveira, J. A., Ridgeway, M. E., & Park, M. A. (2015). Fundamentals of Trapped Ion Mobility Spectrometry. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1007/s13361-014-0999-4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.