Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 179

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Innovative Native MS Methodologies for Antibody Drug Conjugate Characterization: High Resolution Native MS and IM-MS for Average DAR and DAR Distribution Assessment

Debaene, François, Bœuf, Amandine, Wagner-Rousset, Elsa, Colas, Olivier, Ayoub, Daniel, Corvaïa, Nathalie, Van Dorsselaer, Alain, Beck, Alain, Cianférani, Sarah · 2014 · Analytical Chemistry

Abstract

Antibody drug conjugates (ADCs) are macromolecules composed of cytotoxic drugs covalently attached via a conditionally stable linker to monoclonal antibodies (mAbs). ADCs are among the most promising next generation of empowered mAbs foreseen to treat cancers. Compared to naked mAbs, ADCs have an increased level of complexity as the heterogeneity of conjugation cumulates with the inherent microvariability of the biomolecule. An increasing need underlying ADC's development and optimization is to improve its analytical and bioanalytical characterization by assessing three main ADC quality attributes: drug distribution, amount of naked antibody, and average drug to antibody ratio (DAR). Here, the analytical potential of native mass spectrometry (MS) and native ion mobility MS (IM-MS) is compared to hydrophobic interaction chromatography (HIC), the reference method for quality control of interchain cysteinyl-linked ADCs. Brentuximab vedotin, first in class and gold standard, was chosen for a proof of principle. High resolution native MS provided accurate mass measurement (<30 ppm) of intact ADCs together with average DAR and drug distribution, confirming the unique ability of native MS for simultaneous detection of mixtures of covalent and noncovalent products. Native IM-MS was next used for the first time to characterize an ADC. IM-MS evidenced ADC multiple drug loading, collisional cross sections measurement of each payload species attesting slight conformational changes. A semiquantitative interpretation of IM-MS data was developed to directly extrapolate average DAR and DAR distribution. Additionally, HIC fractions were collected and analyzed by native MS and IM-MS, assessing the interpretation of each HIC peak. Altogether, our results illustrate how native MS and IM-MS can rapidly assess ADC structural heterogeneity and how easily these methods can be implemented into MS workflows for in-depth ADC analytical characterization.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac502593n

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 179

Metadata

Authors
Debaene, F., Bœuf, A., Wagner-Rousset, E., Colas, O., Ayoub, D., Corvaïa, N., Van Dorsselaer, A., Beck, A., & Cianférani, S.
Venue
Analytical Chemistry
Published
2014-10-21
Volume
86
Issue
21
Pages
10674-10683
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2326825336
Cited by
179
References
2
FWCI
9.52
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Innovative Native MS Methodologies for Antibody Drug Conjugate Characterization: High Resolution Native MS and IM-MS for Average DAR and DAR Distribution Assessment. https://app.cochat.ai/papers/10.1021/ac502593n
The paper
Debaene, F., Bœuf, A., Wagner-Rousset, E., Colas, O., Ayoub, D., Corvaïa, N., Van Dorsselaer, A., Beck, A., & Cianférani, S. (2014). Innovative Native MS Methodologies for Antibody Drug Conjugate Characterization: High Resolution Native MS and IM-MS for Average DAR and DAR Distribution Assessment. Analytical Chemistry. https://doi.org/10.1021/ac502593n

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.