Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 238

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Rapid, Selective, and Ultrasensitive Fluorimetric Analysis of Mercury and Copper Levels in Blood Using Bimetallic Gold–Silver Nanoclusters with “Silver Effect”-Enhanced Red Fluorescence

Zhang, Ning, Si, Yanmei, Sun, Zongzhao, Chen, Lijun, Li, Rui, Qiao, Yuchun, Wang, Hua·2014·Analytical Chemistry

Abstract

Bimetallic alloying gold-silver nanoclusters (Au-AgNCs) have been synthesized by a one-pot biomineralization synthesis route at a vital molar ratio of Au/Ag precursors in the protein matrix. Unexpectedly, the prepared Au-AgNCs could exhibit dramatically enhanced red fluorescence, which is about 6.5-fold and 4.7-fold higher than that of common AuNCs and core-shell Au@AgNCs, respectively. A rapid, selective, and ultrasensitive fluorimetric method has thereby been developed using Au-AgNCs as fluorescent probes toward the separate detections of Hg(2+) and Cu(2+) ions in blood. The interactions of Au-AgNCs with Hg(2+) and Cu(2+) ions were systematically characterized by microscopy imaging, UV-vis, and fluorescence measurements. It is demonstrated that the "silver effect" gives the Au-AgNCs probes not only greatly enhanced red fluorescence but also the strong capacity to specifically sense Cu(2+) ions in addition to improved response to Hg(2+) ions. Moreover, aided by a Cu(2+) chelating agent, exclusive detection of Hg(2+) ions could also be expected with the coexistence of a high level of Cu(2+) ions, as well as reversible Cu(2+) analysis by restoring the fluorescence of Au-AgNCs. Additionally, Au-AgNCs with strong red fluorescence could facilitate fluorimetric analysis with minimal interference from blood backgrounds. Such an Au-AgNCs-based fluorimetric method can allow for the selective analysis of Hg(2+) and Cu(2+) ions down to 0.30 nM and 0.60 nM in blood, respectively, promising a novel detection method to be applied in the clinical laboratory.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac503102g

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 238

Metadata

Authors
Zhang, N., Si, Y., Sun, Z., Chen, L., Li, R., Qiao, Y., & Wang, H.
Venue
Analytical Chemistry
Published
2014-11-10
Volume
86
Issue
23
Pages
11714-11721
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2331059636
Cited by
238
References
4
FWCI
9.23
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Rapid, Selective, and Ultrasensitive Fluorimetric Analysis of Mercury and Copper Levels in Blood Using Bimetallic Gold–Silver Nanoclusters with “Silver Effect”-Enhanced Red Fluorescence. https://app.cochat.ai/papers/10.1021/ac503102g
The paper
Zhang, N., Si, Y., Sun, Z., Chen, L., Li, R., Qiao, Y., & Wang, H. (2014). Rapid, Selective, and Ultrasensitive Fluorimetric Analysis of Mercury and Copper Levels in Blood Using Bimetallic Gold–Silver Nanoclusters with “Silver Effect”-Enhanced Red Fluorescence. Analytical Chemistry. https://doi.org/10.1021/ac503102g

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.