Selective, Highly Sensitive Fluorescent Probe for the Detection of Sulfur Dioxide Derivatives in Aqueous and Biological Environments
Abstract
On the basis of a unique nucleophilic addition reaction, a novel water-soluble broadly emitting (500-700 nm) fluorescent Probe 1 was developed for the rapid detection of SO2 derivatives in aqueous media. The positively-charged benzopyrylium moiety in Probe 1 provides both excellent water solubility, making this probe applicable in 100% aqueous environments, and the ability to function as a fluorescence quencher of the coumarin moiety. Probe 1 generates a nearly instantaneous strong fluorescence signal in response to SO2 derivatives having an 8.3 nM detection limit for bisufite. The resulting Probe 1-sulfite adduct emits in the green/red spectral region (λ(max) = 585 nm) with a large Stokes shift (139 nm). The probe exhibits excellent selectivity toward SO2 derivatives over other potential interfering agents including reactive sulfur-containing species. Importantly, we demonstrate that Probe 1 can be used for the real-time sensing and bioimaging of SO2 derivatives in living cells.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
A highly sensitive fluorescent probe has proven very effective in detecting sulfur dioxide derivatives because of its unique selectivity to these chemical substances.
“The first one is a highly sensitive fluorescent probe, which has proven to be very effective in detecting sulfur dioxide derivatives because of its unique selectivity to these chemical substances [105].”
From Current Status and Future Trends in Removal, Control, and Mitigation of Algae Food Safety Risks for Human Consumption (2022) · cites this paper as [105]
The citation lists haven’t been fetched yet
References 39 · Cited by 196
- Authors
- Chen, W., Fang, Q., Yang, D., Zhang, H., Song, X., & Foley, J.
- Affiliations
- Central South University (CN)
- Chinese Academy of Sciences (CN)
- Harvard University (US)
- Corresponding author
- Song, Xiangzhi
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-12-08
- Volume
- 87
- Issue
- 1
- Pages
- 609-616
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2328808784
- Cited by
- 196
- References
- 39
- Citations by year
- 2026: 10 · 2025: 7 · 2024: 7 · 2023: 16 · 2022: 13 · 2021: 19 · 2020: 19 · 2019: 34 · 2018: 25 · 2017: 17 · 2016: 20 · 2015: 9
- FWCI
- 6.56
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Fundamental Research Funds, Central South University
- State Key Laboratory of Fine Chemicals, Dalian University Of Technology (KF1202)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Molecular Sensors and Ion Detection
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biochemistry › Sulfur Compounds in Biology
- Physical Sciences › Materials Science › Materials Chemistry › Luminescence and Fluorescent Materials
- Keywords
- fluorescent probes, sulfur dioxide derivatives, sulfite detection, bisulfite, nucleophilic addition, water-soluble probe, aqueous solution sensing, bioimaging, real-time sensing, reactive sulfur species
- MeSH terms
- Carcinoma, Squamous Cell, Fluorescence, Fluorescent Dyes, Humans, Sulfur Dioxide, Tumor Cells, Cultured, Water, Cell Proliferation, Hep G2 Cells, Limit of Detection
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review