Photonic Nanosensor for Colorimetric Detection of Metal Ions
Open accessAbstract
The real-time sensing of metal ions at point of care requires integrated sensors with low energy and sample consumption, reversibility, and rapid recovery. Here, we report a photonic nanosensor that reversibly and quantitatively reports on variation in the concentrations of Pb(2+) and Cu(2+) ions in aqueous solutions (<500 μL) in the visible region of the spectrum (λ(max) ≈ 400-700 nm). A single 6 ns laser pulse (λ = 532 nm) was used to pattern an ∼10 μm thick photosensitive recording medium. This formed periodic AgBr nanocrystal (ø ∼ 5-20 nm) concentrated regions, which produced Bragg diffraction upon illumination with a white light source. The sensor functionalized with 8-hydroxyquinoline allowed sensing through inducing Donnan osmotic pressure and tuning its lattice spacing. The sensor quantitatively measured Pb(2+) and Cu(2+) ion concentrations within the dynamic range of 0.1-10.0 mM with limits of detection of 11.4 and 18.6 μM in under 10 min. The sensor could be reset in 3 min and was reused at least 100 times without compromising its accuracy. The plasmonic nanosensor represents a simple and label-free analytical platform with potential scalability for applications in medical diagnostics and environmental monitoring.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Microcontact printing has been utilized to fabricate a flash memory based on a high-density Ag nanoparticle charge trapping layer on a flexible PET substrate.
“Microcontact printing has been utilized to fabricate a flash memory based on a high‐density Ag nanoparticle charge trapping layer on a flexible polyethylene terephthalate (PET) substrate.95”
From Wearables in Medicine (2018) · cites this paper as [95]
Compared to floating gate memory devices, a memory window of 16.5 V and retention time of 105 s was achieved.
“As compared to memory devices featuring a floating gate, a memory window of 16.5 V and retention time of 105 s was achieved.”
From Wearables in Medicine (2018) · cites this paper as [95]
Cites
Contact Lens Sensors in Ocular Diagnostics
Farandos, N. M., Yetisen, A. K., Monteiro, M. J., Lowe, C. R., & Yun, S. H. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201400504 · Cited by 466 · see citing works
Self-citationA smartphone algorithm with inter-phone repeatability for the analysis of colorimetric tests
Yetisen, A. K., Martinez-Hurtado, J. L., Garcia-Melendrez, A., da Cruz Vasconcellos, F., & Lowe, C. R. (2014) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2014.01.077 · Cited by 285 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Yetisen, A. K., Martinez‐Hurtado, J. L., Ünal, B., Khademhosseini, A., & Butt, H. (2018) · Advanced Materials · doi:10.1002/adma.201706910 · Cited by 569 · see citing works
Self-citationColor-selective holographic retroreflector array for sensing applications
Ahmed, R., Yetisen, A. K., Yun, S. H., & Butt, H. (2016) · Light: Science & Applications · doi:10.1038/lsa.2016.214 · Cited by 57 · see citing works
Self-citation
- Authors
- Yetisen, A. K., Montelongo, Y., Qasim, M. M., Butt, H., Wilkinson, T. D., Monteiro, M. J., & Yun, S. H.
- Affiliations
- Harvard University (US)
- University of Cambridge (GB)
- University of Birmingham (GB)
- The University of Queensland (AU)
- Corresponding author
- Yetisen, Ali K.
- ORCID
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2015-02-24
- Volume
- 87
- Issue
- 10
- Pages
- 5101-5108
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2060571333
- Cited by
- 94
- References
- 2
- Citations by year
- 2026: 3 · 2025: 3 · 2024: 5 · 2023: 6 · 2022: 6 · 2021: 8 · 2020: 7 · 2019: 7 · 2018: 10 · 2017: 5 · 2016: 16 · 2015: 10 · 2014: 7
- FWCI
- 4.47
- Type
- journal article
- Language
- en
- Open access
- green
- www.scopus.com
- Licence
- other-oa
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion, other-oa)
- Cambridge University Engineering Department Publications Database (submittedVersion)
- Funders
- University of Cambridge
- Engineering and Physical Sciences Research Council (EP/I033491/1)
- Topics
- Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Gold and Silver Nanoparticles Synthesis and Applications
- Physical Sciences › Chemical Engineering › Bioengineering › Analytical Chemistry and Sensors
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Photonic Crystals and Applications
- Keywords
- lead ions, copper ions, Bragg diffraction, 8-hydroxyquinoline, plasmonic sensing, point-of-care testing, label-free detection, visible light detection
- MeSH terms
- Colorimetry, Copper, Lead, Models, Molecular, Molecular Conformation, Water, Photons, Hydrogels, Nanotechnology, Nanoparticles
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review