Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 158

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

MALDI-TOF MS Imaging of Metabolites with a N-(1-Naphthyl) Ethylenediamine Dihydrochloride Matrix and Its Application to Colorectal Cancer Liver Metastasis

Wang, Jianing, Qiu, Shulan, Chen, Suming, Xiong, Caiqiao, Liu, Huihui, Wang, Jiyun, Zhang, Ning, Hou, Jian, He, Qing, Nie, Zongxiu · 2015 · Analytical Chemistry

Abstract

Matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI MSI) is a label-free technique for identifying multiplex metabolites and determining both their distribution and relative abundance in situ. Our previous study showed that N-(1-naphthyl) ethylenediamine dihydrochloride (NEDC) could act as a matrix for laser desorption/ionization time-of-flight mass spectrometry (LDI-TOF MS) detection of oligosaccharides in solution. In the present study, NEDC-assisted LDI-TOF MSI yielded many more endogenous compound peaks between m/z 60 and m/z 1600 than 9-aminoacridine (9-AA). Our results show that NEDC-assisted LDI-TOF MSI is especially well-suited for examining distributions of glycerophospholipids (GPs) in addition to low molecular weight metabolites below m/z 400. Particularly, NEDC matrix allowed the LDI-TOF MSI of glucose in animal tissue. Furthermore, NEDC-assisted LDI-TOF MSI was applied to a mouse model of colorectal cancer liver metastasis. We revealed the distinct spatio-molecular signatures of many detected compounds in tumor or tumor-bearing liver, and we found that taurine, glucose, and some GPs decreased in tumor-bearing liver as the tumor developed in liver. Importantly, we also found a glucose gradient in metastatic tumor foci for the first time, which further confirms the energy competition between tumors and liver remnant due to the Warburg effect. Our results suggest that NEDC-assisted LDI MSI provides an in situ label-free analysis of multiple glycerophospholipids and low molecular weight metabolites (including glucose) with abundant peaks and high spatial resolution. This will allow future application to in situ definition of biomarkers, signaling pathways, and disease mechanisms.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac504294s

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 158

Metadata

Authors
Wang, J., Qiu, S., Chen, S., Xiong, C., Liu, H., Wang, J., Zhang, N., Hou, J., He, Q., & Nie, Z.
Venue
Analytical Chemistry
Published
2014-12-12
Volume
87
Issue
1
Pages
422-430
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2320572375
Cited by
158
References
5
FWCI
4.49
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.