The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Carbon Quantum Dots-Based Recyclable Real-Time Fluorescence Assay for Alkaline Phosphatase with Adenosine Triphosphate as Substrate
Abstract
A convenient, reliable, and highly sensitive real-time assay for alkaline phosphatase (ALP) activity in the continuous and recyclable way is established on the basis of aggregation and disaggregation of carbon quantum dots (CQDs) through the competitive assay approach. CQDs and adenosine triphosphate (ATP) were used as the fluorescent indicator and substrate for ALP activity assessment, respectively. Richness of carboxyl groups on the surface of CQDs enables their severe aggregation triggered by cerium ions, which results in effective fluorescence quenching. Under the catalytic hydrolysis of ALP, ATP can be rapidly transformed to phosphate ions. Stronger affinity of phosphate ions to cerium ions than carboxyl groups is taken advantage of to achieve fluorescence recovery induced by redispersion of CQDs in the presence of ALP and ATP. Quantitative evaluation of ALP activity in a broad range from 4.6 to 383.3 U/L with the detection limit of 1.4 U/L can be realized in this way, which endows the assay with high enough sensitivity for practical detection in human serum. The assay can be used in a recyclable way for more than three times since the generated product CePO4 as a precipitate can be easily removed from the standard assay system. This strategy broadens the sensing application of fluorescent CQDs with excellent biocompatibility and provides an example based on disaggregation in optical probe development.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mammalian Alkaline Phosphatases: From Biology to Applications in Medicine and Biotechnology
Millán, J. L. (2006) · doi:10.1002/3527608060 · Cited by 421
Cited by
Fluorescent carbon dots and their sensing applications
Sun, X., & Lei, Y. (2017) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2017.02.001 · Cited by 839
Carbon quantum dots from natural resource: A review
Das, R., Bandyopadhyay, R., & Pramanik, P. (2018) · Materials Today Chemistry · doi:10.1016/j.mtchem.2018.03.003 · Cited by 804
Carbon dots: large-scale synthesis, sensing and bioimaging
Zhang, J., & Yu, S.-H. (2016) · Materials Today · doi:10.1016/j.mattod.2015.11.008 · Cited by 724
Carbon dots: Biomacromolecule interaction, bioimaging and nanomedicine
Peng, Z., Han, X., Li, S., Al-Youbi, A. O., Bashammakh, A. S., El-Shahawi, M. S., & Leblanc, R. M. (2017) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2017.06.001 · Cited by 411
Xi, C.-Y., Zhang, M., Jiang, L., Chen, H.-Y., Lv, J., He, Y., Hafez, M. E., Qian, R.-C., & Li, D.-W. (2022) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2022.132264 · Cited by 42
Metadata
- Authors
- Qian, Z., Chai, L., Tang, C., Huang, Y., Chen, J., & Feng, H.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2015-02-13
- Volume
- 87
- Issue
- 5
- Pages
- 2966-2973
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2332509679
- Cited by
- 207
- References
- 1
- FWCI
- 12.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.