Improving Label-Free Quantitative Proteomics Strategies by Distributing Shared Peptides and Stabilizing Variance
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
In a previous study, we demonstrated that spectral counts-based label-free proteomic quantitation could be improved by distributing peptides shared between multiple proteins. Here, we compare four quantitative proteomic approaches, namely, the normalized spectral abundance factor (NSAF), the normalized area abundance factor (NAAF), normalized parent ion intensity abundance factor (NIAF), and the normalized fragment ion intensity abundance factor (NFAF). We demonstrate that label-free proteomic quantitation methods based on chromatographic peak area (NAAF), parent ion intensity in MS1 (NIAF), and fragment ion intensity (NFAF) are also improved when shared peptides are distributed on the basis of peptides unique to each isoform. To stabilize the variance inherent to label-free proteomic quantitation data sets, we use cyclic-locally weighted scatter plot smoothing (LOWESS) and linear regression normalization (LRN). Again, all four methods are improved when cyclic-LOWESS and LRN are applied to reduce variation. Finally, we demonstrate that absolute quantitative values may be derived from label-free parameters such as spectral counts, chromatographic peak area, and ion intensity when using spiked-in proteins of known amounts to generate standard curves.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lu, P., Vogel, C., Wang, R., Yao, X., & Marcotte, E. M. (2007) · Nature Biotechnology · doi:10.1038/nbt1270 · Cited by 1,139
Quantitative mass spectrometry in proteomics: critical review update from 2007 to the present
Bantscheff, M., Lemeer, S., Savitski, M. M., & Kuster, B. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-6203-4 · Cited by 801
Full dynamic range proteome analysis of S. cerevisiae by targeted proteomics
Picotti, P., Bodenmiller, B., Mueller, L. N., Domon, B., & Aebersold, R. (2009) · Cell · doi:10.1016/j.cell.2009.05.051 · Cited by 744
Significance Analysis of Spectral Count Data in Label-free Shotgun Proteomics
Choi, H., Fermin, D., & Nesvizhskii, A. I. (2008) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m800203-mcp200 · Cited by 364
Cited by
Quantitative high-confidence human mitochondrial proteome and its dynamics in cellular context
Morgenstern, M., Peikert, C. D., Lübbert, P., Suppanz, I., Klemm, C., Alka, O., Steiert, C., Naumenko, N., Schendzielorz, A., Melchionda, L., et al. (2021) · Cell Metabolism · doi:10.1016/j.cmet.2021.11.001 · Cited by 323
Phosphoproteomics in the Age of Rapid and Deep Proteome Profiling
Riley, N. M., & Coon, J. J. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b04123 · Cited by 265
Multiple testing corrections in quantitative proteomics: A useful but blunt tool
Pascovici, D., Handler, D. C. L., Wu, J. X., & Haynes, P. A. (2016) · PROTEOMICS · doi:10.1002/pmic.201600044 · Cited by 218
“These issues are outside the scope of this note and simple simulations, and separate methods or tools have been devised to account for them; more sophisticated statistical models for iTRAQ analysis [12–14], and different normalization and analysis approaches for NSAF data [15, 16]).”
Gao, J., Mfuh, A., Amako, Y., & Woo, C. M. (2018) · Journal of the American Chemical Society · doi:10.1021/jacs.7b11639 · Cited by 102
Metadata
- Authors
- Zhang, Y., Wen, Z., Washburn, M. P., & Florens, L.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2015-04-13
- Volume
- 87
- Issue
- 9
- Pages
- 4749-4756
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2318359812
- Cited by
- 43
- References
- 4
- FWCI
- 1.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.