CoChat

Elimination of Systematic Mass Measurement Errors in Liquid Chromatography−Mass Spectrometry Based Proteomics Using Regression Models and a Priori Partial Knowledge of the Sample Content

Open access
Petyuk, Vladislav A., Jaitly, Navdeep, Moore, Ronald J., Ding, Jie, Metz, Thomas O., Tang, Keqi, Monroe, Matthew E., Tolmachev, Aleksey V., Adkins, Joshua N., Belov, Mikhail E., Dabney, Alan R., Qian, Wei-Jun, Camp, David G., Smith, Richard D. · 2008 · Analytical Chemistry
Cited by 46

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The high mass measurement accuracy and precision available with recently developed mass spectrometers is increasingly used in proteomics analyses to confidently identify tryptic peptides from complex mixtures of proteins, as well as post-translational modifications and peptides from nonannotated proteins. To take full advantage of high mass measurement accuracy instruments, it is necessary to limit systematic mass measurement errors. It is well known that errors in m/z measurements can be affected by experimental parameters that include, for example, outdated calibration coefficients, ion intensity, and temperature changes during the measurement. Traditionally, these variations have been corrected through the use of internal calibrants (well-characterized standards introduced with the sample being analyzed). In this paper, we describe an alternative approach where the calibration is provided through the use of a priori knowledge of the sample being analyzed. Such an approach has previously been demonstrated based on the dependence of systematic error on m/z alone. To incorporate additional explanatory variables, we employed multidimensional, nonparametric regression models, which were evaluated using several commercially available instruments. The applied approach is shown to remove any noticeable biases from the overall mass measurement errors and decreases the overall standard deviation of the mass measurement error distribution by 1.2-2-fold, depending on instrument type. Subsequent reduction of the random errors based on multiple measurements over consecutive spectra further improves accuracy and results in an overall decrease of the standard deviation by 1.8-3.7-fold. This new procedure will decrease the false discovery rates for peptide identifications using high-accuracy mass measurements.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac701863d

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 46

Metadata

Authors
Petyuk, V. A., Jaitly, N., Moore, R. J., Ding, J., Metz, T. O., Tang, K., Monroe, M. E., Tolmachev, A. V., Adkins, J. N., Belov, M. E., Dabney, A. R., Qian, W.-J., Camp, D. G., & Smith, R. D.
Venue
Analytical Chemistry
Published
2007-12-29
Volume
80
Issue
3
Pages
693-706
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2076872808
Cited by
46
References
1
FWCI
1.74
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Elimination of Systematic Mass Measurement Errors in Liquid Chromatography−Mass Spectrometry Based Proteomics Using Regression Models and a Priori Partial Knowledge of the Sample Content. https://app.cochat.ai/papers/10.1021/ac701863d
The paper
Petyuk, V. A., Jaitly, N., Moore, R. J., Ding, J., Metz, T. O., Tang, K., Monroe, M. E., Tolmachev, A. V., Adkins, J. N., Belov, M. E., Dabney, A. R., Qian, W.-J., Camp, D. G., & Smith, R. D. (2008). Elimination of Systematic Mass Measurement Errors in Liquid Chromatography−Mass Spectrometry Based Proteomics Using Regression Models and a Priori Partial Knowledge of the Sample Content. Analytical Chemistry. https://doi.org/10.1021/ac701863d

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.