The DOI matches its Crossref record.
Nanoparticle-Assisted Laser Desorption/Ionization Based Mass Imaging with Cellular Resolution
Abstract
Today, two-dimensional mass spectrometry analysis of biological tissues by means of a technique called mass imaging, mass spectrometry imaging (MSI), or imaging mass spectrometry (IMS) has found application in investigating the distribution of moleculesMSI with matrix-assisted laser desorption/ionization (MALDI) and secondary ion MS (SIMS). However, the size of the matrix crystal and the migration of analytes can decrease the spatial resolution in MALDI, and SIMS can only ionize compounds with relatively low molecular weights. To overcome these problems, we developed a nanoparticle-assisted laser desorption/ionization (nano-PALDI)-based MSI. We used nano-PALDI MSI to visualize lipids and peptides at a resolution of 15 microm in mammalian tissues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bioimaging of metals by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS)
Becker, J. S., Zoriy, M., Matusch, A., Wu, B., Salber, D., Palm, C., & Becker, J. S. (2010) · Mass Spectrometry Reviews · doi:10.1002/mas.20239 · Cited by 287
Kajimura, M., Fukuda, R., Bateman, R. M., Yamamoto, T., & Suematsu, M. (2010) · Antioxidants & Redox Signaling · doi:10.1089/ars.2009.2657 · Cited by 266
Metadata
- Authors
- Taira, S., Sugiura, Y., Moritake, S., Shimma, S., Ichiyanagi, Y., & Setou, M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-05-14
- Volume
- 80
- Issue
- 12
- Pages
- 4761-4766
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2017349873
- Cited by
- 170
- References
- 0
- FWCI
- 8.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nanoparticle-Assisted Laser Desorption/Ionization Based Mass Imaging with Cellular Resolution. https://app.cochat.ai/papers/10.1021/ac800081z
- The paper
- Taira, S., Sugiura, Y., Moritake, S., Shimma, S., Ichiyanagi, Y., & Setou, M. (2008). Nanoparticle-Assisted Laser Desorption/Ionization Based Mass Imaging with Cellular Resolution. Analytical Chemistry. https://doi.org/10.1021/ac800081z
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.