Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 159

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Coreactant Enhanced Anodic Electrochemiluminescence of CdTe Quantum Dots at Low Potential for Sensitive Biosensing Amplified by Enzymatic Cycle

Liu, Xuan, Ju, Huangxian·2008·Analytical Chemistry

Abstract

This work used sulfite as a coreactant to enhance the anodic electrochemiluminescence (ECL) of mercaptopropionic acid modified CdTe quantum dots (QDs). This strategy proposed the first coreactant anodic ECL of QDs and led to a sensitive ECL emission of QDs in aqueous solution at relatively low potential. In the presence of dissolved oxygen, the stable ECL emission resulted from the excited QDs. Thus, an ECL detection method was proposed at +0.90 V (vs Ag/AgCl) based on the quenching of excited QDs by the analyte. Using tyrosine as a model compound, whose electrooxidized product could quench the excited QDs and thus the ECL emission, an analytical method for detection of tyrosine in a wide concentration range was developed. Furthermore, by combining an enzymatic cycle of trace tyrosinase to produce the oxidized product with an energy-transfer process, an extremely sensitive method for ECL detection of tyrosine with a subpicomolar limit of detection was developed. The sulfite-enhanced anodic ECL emission provided an alternative for traditional ECL light emitters and a new methodology for extremely sensitive ECL detection of mono- and dihydroxybenzenes at relatively low anodic potential. This strategy could be easily realized and opened new avenues for the applications of QDs in ECL biosensing.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac8003715

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Metadata

Authors
Liu, X., & Ju, H.
Venue
Analytical Chemistry
Published
2008-06-04
Volume
80
Issue
14
Pages
5377-5382
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2058599528
Cited by
159
References
2
FWCI
10.37
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.