The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Inkjet-Printed Microfluidic Multianalyte Chemical Sensing Paper
Abstract
This paper presents an inkjet printing method for the fabrication of entire microfluidic multianalyte chemical sensing devices made from paper suitable for quantitative analysis, requiring only a single printing apparatus. An inkjet printing device is used for the fabrication of three-dimensional hydrophilic microfluidic patterns (550-mum-wide flow channels) and sensing areas (1.5 mm x 1.5 mm squares) on filter paper, by inkjet etching, and thereby locally dissolving a hydrophobic poly(styrene) layer obtained by soaking of the filter paper in a 1 wt % solution of poly(styrene) in toluene. In a second step, the same inkjet printing device is used to print "chemical sensing inks", comprising the necessary reagents for colorimetric analytical assays, into well-defined areas of the patterned microfluidic paper devices. The arrangement of the patterns, printed inks, and sensing areas was optimized to obtain homogeneous color responses. The results are "all-inkjet-printed" chemical sensing devices for the simultaneous determination of pH, total protein, and glucose in clinically relevant concentration ranges for urine analysis (0.46-46 muM for human serum albumin, 2.8-28.0 mM for glucose, and pH 5-9). Quantitative data are obtained by digital color analysis in the L*a*b* color space by means of a color scanner and a simple computer program.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Cited by
The present and future role of microfluidics in biomedical research
Sackmann, E. K., Fulton, A. L., & Beebe, D. J. (2014) · Nature · doi:10.1038/nature13118 · Cited by 2,995
Diagnostics for the Developing World: Microfluidic Paper-Based Analytical Devices
Martinez, A. W., Phillips, S. T., Whitesides, G. M., & Carrilho, E. (2010) · Analytical Chemistry · doi:10.1021/ac9013989 · Cited by 2,674
Wood-Derived Materials for Green Electronics, Biological Devices, and Energy Applications
Zhu, H., Luo, W., Ciesielski, P. N., Fang, Z., Zhu, J. Y., Henriksson, G., Himmel, M. E., & Hu, L. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00225 · Cited by 1,532
Paper Spray for Direct Analysis of Complex Mixtures Using Mass Spectrometry
Wang, H., Liu, J., Cooks, R. G., & Ouyang, Z. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200906314 · Cited by 771
Microfluidic Paper-Based Analytical Devices: From Design to Applications
Noviana, E., Ozer, T., Carrell, C. S., Link, J. S., McMahon, C., Jang, I., & Henry, C. S. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01335 · Cited by 631
Flexographically Printed Fluidic Structures in Paper
Olkkonen, J., Lehtinen, K., & Erho, T. (2010) · Analytical Chemistry · doi:10.1021/ac1027066 · Cited by 369
Use of multiple colorimetric indicators for paper-based microfluidic devices
Dungchai, W., Chailapakul, O., & Henry, C. S. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2010.06.019 · Cited by 364
Paper-based analytical devices for environmental analysis
Meredith, N. A., Quinn, C., Cate, D. M., Reilly, T. H., Volckens, J., & Henry, C. S. (2016) · The Analyst · doi:10.1039/c5an02572a · Cited by 299
Metadata
- Authors
- Abe, K., Suzuki, K., & Citterio, D.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-08-13
- Volume
- 80
- Issue
- 18
- Pages
- 6928-6934
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1987189499
- Cited by
- 766
- References
- 1
- FWCI
- 18.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.