Flexographically Printed Fluidic Structures in Paper
Abstract
This Technical Note demonstrates a simple method based on flexographic printing of polystyrene to form liquid guiding boundaries and layers on paper substrates. The method allows formation of hydrophobic barrier structures that partially or completely penetrate through the substrate. This unique property enables one to form very thin fluidic channels on paper, leading to reduced sample volumes required in point-of-care diagnostic devices. The described method is compatible with roll-to-roll flexography units found in many printing houses, making it an ideal method for large-scale production of paper-based fluidic structures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Patterned Paper as a Platform for Inexpensive, Low‐Volume, Portable Bioassays
Martinez, A. W., Phillips, S. T., Butte, M. J., & Whitesides, G. M. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200603817 · Cited by 2,874
Diagnostics for the Developing World: Microfluidic Paper-Based Analytical Devices
Martinez, A. W., Phillips, S. T., Whitesides, G. M., & Carrilho, E. (2010) · Analytical Chemistry · doi:10.1021/ac9013989 · Cited by 2,674
Understanding Wax Printing: A Simple Micropatterning Process for Paper-Based Microfluidics
Carrilho, E., Martinez, A. W., & Whitesides, G. M. (2009) · Analytical Chemistry · doi:10.1021/ac901071p · Cited by 1,612
Martinez, A. W., Phillips, S. T., Carrilho, E., Thomas, S. W., Sindi, H., & Whitesides, G. M. (2008) · Analytical Chemistry · doi:10.1021/ac800112r · Cited by 1,443
Three-dimensional microfluidic devices fabricated in layered paper and tape
Martinez, A. W., Phillips, S. T., & Whitesides, G. M. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0810903105 · Cited by 1,246
Inkjet-Printed Microfluidic Multianalyte Chemical Sensing Paper
Abe, K., Suzuki, K., & Citterio, D. (2008) · Analytical Chemistry · doi:10.1021/ac800604v · Cited by 766
FLASH: A rapid method for prototyping paper-based microfluidic devices
Martinez, A. W., Phillips, S. T., Wiley, B. J., Gupta, M., & Whitesides, G. M. (2008) · Lab on a Chip · doi:10.1039/b811135a · Cited by 695
Low-Cost Printing of Poly(dimethylsiloxane) Barriers To Define Microchannels in Paper
Bruzewicz, D. A., Reches, M., & Whitesides, G. M. (2008) · Analytical Chemistry · doi:10.1021/ac702605a · Cited by 616
Bioactive paper provides a low-cost platform for diagnostics
Pelton, R. (2009) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2009.05.005 · Cited by 562
Progress in patterned paper sizing for fabrication of paper-based microfluidic sensors
Li, X., Tian, J., & Shen, W. (2010) · Cellulose · doi:10.1007/s10570-010-9401-2 · Cited by 191
Cited by
The present and future role of microfluidics in biomedical research
Sackmann, E. K., Fulton, A. L., & Beebe, D. J. (2014) · Nature · doi:10.1038/nature13118 · Cited by 2,995
Metadata
- Authors
- Olkkonen, J., Lehtinen, K., & Erho, T.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-11-23
- Volume
- 82
- Issue
- 24
- Pages
- 10246-10250
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2331881304
- Cited by
- 369
- References
- 10
- FWCI
- 7.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Flexographically Printed Fluidic Structures in Paper. https://app.cochat.ai/papers/10.1021/ac1027066
- The paper
- Olkkonen, J., Lehtinen, K., & Erho, T. (2010). Flexographically Printed Fluidic Structures in Paper. Analytical Chemistry. https://doi.org/10.1021/ac1027066
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.