The DOI matches its Crossref record.
Overcoming Matrix Effects in Liquid Chromatography−Mass Spectrometry
Abstract
A major limitation in quantitative analysis with electrospray ionization mass spectrometry (ESI-MS) is represented by the so-called matrix effects in which the matrix coextracted with the analytes can alter the signal response, causing either suppression or enhancement, resulting in poor analytical accuracy, linearity, and reproducibility. In the direct electron ionization liquid chromatography-mass spectrometry (direct-EI LC-MS) interface the ionization process is based on electron impact ionization, and it occurs in the gas phase and is not influenced by coeluted matrix compounds. In this work we quantitatively evaluated matrix effects on enriched environmental and biological samples, with different extraction procedures, using ESI and direct-EI LC-MS. As expected, the samples analyzed with direct-EI were not affected by matrix composition, whereas with ESI we observed either signal suppression or enhancement, depending on the sample nature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ferrer, C., Lozano, A., Agüera, A., Girón, A. J., & Fernández-Alba, A. R. (2011) · Journal of Chromatography A · doi:10.1016/j.chroma.2011.07.033 · Cited by 485
Köhrle, J., & Richards, K. H. (2020) · Experimental and Clinical Endocrinology & Diabetes · doi:10.1055/a-1175-4610 · Cited by 7
Metadata
- Authors
- Cappiello, A., Famiglini, G., Palma, P., Pierini, E., Termopoli, V., & Trufelli, H.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-10-30
- Volume
- 80
- Issue
- 23
- Pages
- 9343-9348
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2087575187
- Cited by
- 253
- References
- 0
- FWCI
- 5.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Overcoming Matrix Effects in Liquid Chromatography−Mass Spectrometry. https://app.cochat.ai/papers/10.1021/ac8018312
- The paper
- Cappiello, A., Famiglini, G., Palma, P., Pierini, E., Termopoli, V., & Trufelli, H. (2008). Overcoming Matrix Effects in Liquid Chromatography−Mass Spectrometry. Analytical Chemistry. https://doi.org/10.1021/ac8018312
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.