The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Characterization of Phosphorylated Peptides Using Traveling Wave-Based and Drift Cell Ion Mobility Mass Spectrometry
Abstract
Phosphorylation is one the most studied and important post translational modifications. Nano electrospray mass spectrometry coupled with traveling wave (T-Wave)-based ion mobility has been used to filter for phosphorylated peptides in tryptic protein digests. T-Wave parameters have been optimized to maximize the separation between phosphorylated and non-phosphorylated peptides. A method to calibrate the T-Wave device, to provide estimates of collision cross sections, is presented, and these estimates are in excellent agreement with values obtained on drift cell instrumentation. Phosphorylated peptides have smaller cross sections which enables their separation from non-phosphorylated peptides of the same m/z. Post-mobility fragmentation is used to obtain the primary sequence for peptides of interest. This approach is shown to have potential as an additional screen for phosphorylated peptides, where up to 40% of observed peptides can be eliminated from the study.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mass spectrometry-based proteomics
Aebersold, R., & Mann, M. (2003) · Nature · doi:10.1038/nature01511 · Cited by 6,955
Large-scale phosphorylation analysis of mouse liver
Villén, J., Beausoleil, S. A., Gerber, S. A., & Gygi, S. P. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0609836104 · Cited by 730
Cited by
Ion Mobility Spectrometry: Fundamental Concepts, Instrumentation, Applications, and the Road Ahead
Dodds, J. N., & Baker, E. S. (2019) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-019-02288-2 · Cited by 574
A Cyclic Ion Mobility-Mass Spectrometry System
Giles, K., Ujma, J., Wildgoose, J., Pringle, S., Richardson, K., Langridge, D., & Green, M. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b01838 · Cited by 510
Recommendations for reporting ion mobility Mass Spectrometry measurements
Gabelica, V., Shvartsburg, A. A., Afonso, C., Barran, P., Benesch, J. L. P., Bleiholder, C., Bowers, M. T., Bilbao, A., Bush, M. F., Campbell, J. L., et al. (2019) · Mass Spectrometry Reviews · doi:10.1002/mas.21585 · Cited by 493
Self-citationLapthorn, C., Pullen, F., & Chowdhry, B. Z. (2013) · Mass Spectrometry Reviews · doi:10.1002/mas.21349 · Cited by 398
Enhancements in travelling wave ion mobility resolution
Giles, K., Williams, J. P., & Campuzano, I. (2011) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.5013 · Cited by 369
Metadata
- Authors
- Thalassinos, K., Grabenauer, M., Slade, S. E., Hilton, G. R., Bowers, M. T., & Scrivens, J. H.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-12-04
- Volume
- 81
- Issue
- 1
- Pages
- 248-254
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2128053367
- Cited by
- 240
- References
- 2
- FWCI
- 7.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.