The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Airway Monitoring by Collection and Mass Spectrometric Analysis of Exhaled Particles
Abstract
We describe a new method for simultaneously collecting particles in exhaled air for subsequent chemical analysis and measuring their size distribution. After forced exhalation, particles were counted and collected in spots on silicon wafers with a cascade impactor. Several phospholipids were identified by time-of-flight secondary ion mass spectrometric analysis of the collected spots, suggesting that the particles originated from the lower airways. The amount of particles collected in ten exhalations was sufficient for characterizing the phospholipid composition. The feasibility of the technique in respiratory research is demonstrated by analysis of the phospholipid composition of exhaled particles from healthy controls, patients with asthma, and patients with cystic fibrosis. We believe this technology will be useful for monitoring patients with respiratory disease and has a high potential to detect new biomarkers in exhaled air.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The size distribution of droplets in the exhaled breath of healthy human subjects
PAPINENI, R. S., & ROSENTHAL, F. S. (1997) · Journal of Aerosol Medicine · doi:10.1089/jam.1997.10.105 · Cited by 690
Inhaling to mitigate exhaled bioaerosols
Edwards, D. A., Man, J. C., Brand, P., Katstra, J. P., Sommerer, K., Stone, H. A., Nardell, E., & Scheuch, G. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0408159101 · Cited by 362
Cited by
A European Respiratory Society technical standard: exhaled biomarkers in lung disease
Horváth, I., Barnes, P. J., Loukides, S., Sterk, P. J., Högman, M., Olin, A.-C., Amann, A., Antus, B., Baraldi, E., Bikov, A., et al. (2017) · European Respiratory Journal · doi:10.1183/13993003.00965-2016 · Cited by 638
Self-citationAirborne spread of infectious agents in the indoor environment
Wei, J., & Li, Y. (2016) · American Journal of Infection Control · doi:10.1016/j.ajic.2016.06.003 · Cited by 519
Exhaled Particles and Small Airways
Bake, B., Larsson, P., Ljungkvist, G., Ljungström, E., & Olin, A.-C. (2019) · Respiratory Research · doi:10.1186/s12931-019-0970-9 · Cited by 218
Self-citation
Metadata
- Authors
- Almstrand, A.-C., Ljungström, E., Lausmaa, J., Bake, B., Sjövall, P., & Olin, A.-C.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-12-05
- Volume
- 81
- Issue
- 2
- Pages
- 662-668
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2040020285
- Cited by
- 170
- References
- 2
- FWCI
- 2.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Airway Monitoring by Collection and Mass Spectrometric Analysis of Exhaled Particles. https://app.cochat.ai/papers/10.1021/ac802055k
- The paper
- Almstrand, A.-C., Ljungström, E., Lausmaa, J., Bake, B., Sjövall, P., & Olin, A.-C. (2009). Airway Monitoring by Collection and Mass Spectrometric Analysis of Exhaled Particles. Analytical Chemistry. https://doi.org/10.1021/ac802055k
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.