The DOI matches its Crossref record.
Detection of Glucose Based on Direct Electron Transfer Reaction of Glucose Oxidase Immobilized on Highly Ordered Polyaniline Nanotubes
Abstract
An amperometric glucose biosensor based on the direct electron transfer of glucose oxidase (GOx) was developed by electrochemically entrapping GOx onto the inner wall of highly ordered polyaniline nanotubes (nanoPANi), which was synthesized using anodic aluminum oxide (AAO) membrane as a template. The cyclic voltammetric results indicated that GOx immobilized on the nanoPANi underwent direct electron transfer reaction, and the cyclic voltammogram displayed a pair of well-defined and nearly symmetric redox peaks with a formal potential of -405 +/- 5 mV and an apparent electron transfer rate constant of 5.8 +/- 1.6 s(-1). The biosensor had good electrocatalytic activity toward oxidation of glucose and exhibited a rapid response (approximately 3 s), a low detection limit (0.3 +/- 0.1 microM), a useful linear range (0.01-5.5 mM), high sensitivity (97.18 +/- 4.62 microA mM(-1) cm(-2)), higher biological affinity (the apparent Michaelis-Mentan constant was estimated to be 2.37 +/- 0.5 mM) as well as good stability and repeatability. In addition, the common interfering species, such as ascorbic acid, uric acid, and 4-acetamidophenol, did not cause any interference due to the use of a low detection potential (-0.3 V vs SCE). The biosensor can also be used for quantification of the concentration of glucose in real clinical samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Glucose Oxidase–graphene–chitosan modified electrode for direct electrochemistry and glucose sensing
Kang, X., Wang, J., Wu, H., Aksay, I. A., Liu, J., & Lin, Y. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.09.004 · Cited by 1,229
Hierarchical nanostructured conducting polymer hydrogel with high electrochemical activity
Pan, L., Yu, G., Zhai, D., Lee, H. R., Zhao, W., Liu, N., Wang, H., Tee, B. C.-K., Shi, Y., Cui, Y., et al. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1202636109 · Cited by 1,216
Recent advances in polyaniline based biosensors
Dhand, C., Das, M., Datta, M., & Malhotra, B. D. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.10.017 · Cited by 522
3D nanostructured conductive polymer hydrogels for high-performance electrochemical devices
Zhao, Y., Liu, B., Pan, L., & Yu, G. (2013) · Energy & Environmental Science · doi:10.1039/c3ee40997j · Cited by 396
Self‐Assembled Graphene–Enzyme Hierarchical Nanostructures for Electrochemical Biosensing
Zeng, Q., Cheng, J., Tang, L., Liu, X., Liu, Y., Li, J., & Jiang, J. (2010) · Advanced Functional Materials · doi:10.1002/adfm.201000540 · Cited by 271
Metadata
- Authors
- Wang, Z., Liu, S., Wu, P., & Cai, C.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-01-26
- Volume
- 81
- Issue
- 4
- Pages
- 1638-1645
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2064887259
- Cited by
- 307
- References
- 0
- FWCI
- 26.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection of Glucose Based on Direct Electron Transfer Reaction of Glucose Oxidase Immobilized on Highly Ordered Polyaniline Nanotubes. https://app.cochat.ai/papers/10.1021/ac802421h
- The paper
- Wang, Z., Liu, S., Wu, P., & Cai, C. (2009). Detection of Glucose Based on Direct Electron Transfer Reaction of Glucose Oxidase Immobilized on Highly Ordered Polyaniline Nanotubes. Analytical Chemistry. https://doi.org/10.1021/ac802421h
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.