Disposable Nucleic Acid Biosensors Based on Gold Nanoparticle Probes and Lateral Flow Strip

Mao, Xun, Ma, Yunqing, Zhang, Aiguo, Zhang, Lurong, Zeng, Lingwen, Liu, Guodong·2009·Analytical Chemistry

Abstract

In this article, we describe a disposable nucleic acid biosensor (DNAB) for low-cost and sensitive detection of nucleic acid samples in 15 min. Combining the unique optical properties of gold nanoparticles (Au-NP) and the high efficiency of chromatographic separation, sandwich-type DNA hybridization reactions were realized on the lateral flow strips, which avoid multiple incubation, separation, and washing steps in the conventional nucleic acid biosensors. The captured Au-NP probes on the test zone and control zone of the biosensor produced the characteristic red bands, enabling visual detection of nucleic acid samples without instrumentation. The quantitative detection was performed by reading the intensities of the produced red bands with a portable strip reader. The parameters (e.g., the concentration of reporter probe, the size of Au-NP, the amount of Au-NP-DNA probe, lateral flow membranes, and the concentration of running buffer) that govern the sensitivity and reproducibility of the sensor were optimized. The response of the optimized device is highly linear over the range of 1-100 nM target DNA, and the limit of detection is estimated to be 0.5 nM in association with a 15 min assay time. The sensitivity of the biosensor was further enhanced by using horseradish peroxidase (HRP)-Au-NP dual labels which ensure a quite low detection limit of 50 pM. The DNAB has been applied for the detection of human genomic DNA directly with a detection limit of 2.5 microg/mL (1.25 fM) by adopting well-designed DNA probes. The new nucleic acid biosensor thus provides a rapid, sensitive, low cost, and quantitative tool for the detection of nucleic acid samples. It shows great promise for in-field and point-of-care diagnosis of genetic diseases and detection of infectious agents or warning against biowarfare agents.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac8024653

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 344

Metadata

Authors
Mao, X., Ma, Y., Zhang, A., Zhang, L., Zeng, L., & Liu, G.
Venue
Analytical Chemistry
Published
2009-01-21
Volume
81
Issue
4
Pages
1660-1668
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W1970801243
Cited by
344
References
1
FWCI
12.62
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Disposable Nucleic Acid Biosensors Based on Gold Nanoparticle Probes and Lateral Flow Strip. https://app.cochat.ai/papers/10.1021/ac8024653
The paper
Mao, X., Ma, Y., Zhang, A., Zhang, L., Zeng, L., & Liu, G. (2009). Disposable Nucleic Acid Biosensors Based on Gold Nanoparticle Probes and Lateral Flow Strip. Analytical Chemistry. https://doi.org/10.1021/ac8024653

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.