The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Disposable Nucleic Acid Biosensors Based on Gold Nanoparticle Probes and Lateral Flow Strip
Abstract
In this article, we describe a disposable nucleic acid biosensor (DNAB) for low-cost and sensitive detection of nucleic acid samples in 15 min. Combining the unique optical properties of gold nanoparticles (Au-NP) and the high efficiency of chromatographic separation, sandwich-type DNA hybridization reactions were realized on the lateral flow strips, which avoid multiple incubation, separation, and washing steps in the conventional nucleic acid biosensors. The captured Au-NP probes on the test zone and control zone of the biosensor produced the characteristic red bands, enabling visual detection of nucleic acid samples without instrumentation. The quantitative detection was performed by reading the intensities of the produced red bands with a portable strip reader. The parameters (e.g., the concentration of reporter probe, the size of Au-NP, the amount of Au-NP-DNA probe, lateral flow membranes, and the concentration of running buffer) that govern the sensitivity and reproducibility of the sensor were optimized. The response of the optimized device is highly linear over the range of 1-100 nM target DNA, and the limit of detection is estimated to be 0.5 nM in association with a 15 min assay time. The sensitivity of the biosensor was further enhanced by using horseradish peroxidase (HRP)-Au-NP dual labels which ensure a quite low detection limit of 50 pM. The DNAB has been applied for the detection of human genomic DNA directly with a detection limit of 2.5 microg/mL (1.25 fM) by adopting well-designed DNA probes. The new nucleic acid biosensor thus provides a rapid, sensitive, low cost, and quantitative tool for the detection of nucleic acid samples. It shows great promise for in-field and point-of-care diagnosis of genetic diseases and detection of infectious agents or warning against biowarfare agents.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Drummond, T. G., Hill, M. G., & Barton, J. K. (2003) · Nature Biotechnology · doi:10.1038/nbt873 · Cited by 2,214
Cited by
Gold nanoparticles: preparation, properties, and applications in bionanotechnology
Yeh, Y.-C., Creran, B., & Rotello, V. M. (2012) · Nanoscale · doi:10.1039/c1nr11188d · Cited by 1,346
Advances in paper-based point-of-care diagnostics
Hu, J., Wang, S., Wang, L., Li, F., Pingguan-Murphy, B., Lu, T. J., & Xu, F. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.10.075 · Cited by 956
Designs, formats and applications of lateral flow assay: A literature review
Sajid, M., Kawde, A.-N., & Daud, M. (2015) · Journal of Saudi Chemical Society · doi:10.1016/j.jscs.2014.09.001 · Cited by 765
A SERS-based lateral flow assay biosensor for highly sensitive detection of HIV-1 DNA
Fu, X., Cheng, Z., Yu, J., Choo, P., Chen, L., & Choo, J. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.11.099 · Cited by 377
Point of care testing: The impact of nanotechnology
Syedmoradi, L., Daneshpour, M., Alvandipour, M., Gomez, F. A., Hajghassem, H., & Omidfar, K. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.08.084 · Cited by 367
An Aptamer Cross‐Linked Hydrogel as a Colorimetric Platform for Visual Detection
Zhu, Z., Wu, C., Liu, H., Zou, Y., Zhang, X., Kang, H., Yang, C. J., & Tan, W. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200905570 · Cited by 364
The Era of Digital Health: A Review of Portable and Wearable Affinity Biosensors
Tu, J., Torrente‐Rodríguez, R. M., Wang, M., & Gao, W. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201906713 · Cited by 357
Wang, X., Xiong, E., Tian, T., Cheng, M., Lin, W., Wang, H., Zhang, G., Sun, J., & Zhou, X. (2020) · ACS Nano · doi:10.1021/acsnano.0c00022 · Cited by 326
Baker, A. N., Richards, S.-J., Guy, C. S., Congdon, T. R., Hasan, M., Zwetsloot, A. J., Gallo, A., Lewandowski, J. R., Stansfeld, P. J., Straube, A., et al. (2020) · ACS Central Science · doi:10.1021/acscentsci.0c00855 · Cited by 303
Lateral-flow technology: From visual to instrumental
Mak, W. C., Beni, V., & Turner, A. P. F. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.10.017 · Cited by 264
The application of nanoparticles in point-of-care testing (POCT) immunoassays
Hou, F., Sun, S., Abdullah, S. W., Tang, Y., Li, X., & Guo, H. (2023) · Analytical Methods · doi:10.1039/d3ay00182b · Cited by 61
Metadata
- Authors
- Mao, X., Ma, Y., Zhang, A., Zhang, L., Zeng, L., & Liu, G.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-01-21
- Volume
- 81
- Issue
- 4
- Pages
- 1660-1668
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1970801243
- Cited by
- 344
- References
- 1
- FWCI
- 12.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.