The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Surface Plasmon Resonance Detection Using Antibody-Linked Magnetic Nanoparticles for Analyte Capture, Purification, Concentration, and Signal Amplification
Open accessAbstract
Rapid, sensitive, and accurate detection of analytes present in low concentrations in complex matrixes is a critical challenge. One issue that affects many biosensor protocols is the number and nature of the interferences present in complex matrixes such as plasma, urine, stool, and environmental samples, resulting in loss of sensitivity and specificity. We have developed a method for rapid purification, concentration, and detection of target analytes from complex matrixes using antibody-coated superparamagnetic nanobeads (immunomagnetic beads, or IMBs). The surface plasmon resonance (SPR) detection signal from staphylococcal enterotoxin B (SEB) was dramatically increased when the IMBs were used as detection amplifiers. When SEB detection included a 10-fold concentration/purification IMB protocol, a substantial increase in detection sensitivity was observed. This procedure was used to successfully purify and concentrate SEB from serum and stool samples, then amplify the SPR detection signal. SEB at a concentration of 100 pg/mL was easily detected in both buffer and stool samples using this procedure. The IMB protocol also served to verify the analyte detection by using two different anti-SEB antibodies, mouse monoclonal antibodies attached to the magnetic nanobeads and rabbit polyclonal antibodies on the SPR sensor surface. Multiple detections of SEB in stool were performed using the same sensor surface by regenerating the sensor surfaces with a pH 2.2 buffer wash.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stevens, R. C., Soelberg, S. D., Near, S., & Furlong, C. E. (2008) · Analytical Chemistry · doi:10.1021/ac800892h · Cited by 179
Self-citation
Cited by
Surface Plasmon Resonance: A Versatile Technique for Biosensor Applications
Nguyen, H., Park, J., Kang, S., & Kim, M. (2015) · Sensors · doi:10.3390/s150510481 · Cited by 1,357
Microfluidic Applications of Magnetic Particles for Biological Analysis and Catalysis
Gijs, M. A. M., Lacharme, F., & Lehmann, U. (2010) · Chemical Reviews · doi:10.1021/cr9001929 · Cited by 679
Plasmonic Biosensing: Focus Review
Mejía-Salazar, J. R., & Oliveira, O. N. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00359 · Cited by 544
Magnetic nanoparticles in biomedical applications: A review
Materón, E. M., Miyazaki, C. M., Carr, O., Joshi, N., Picciani, P. H. S., Dalmaschio, C. J., Davis, F., & Shimizu, F. M. (2021) · Applied Surface Science Advances · doi:10.1016/j.apsadv.2021.100163 · Cited by 456
Advances and challenges in biosensor-based diagnosis of infectious diseases
Sin, M. L., Mach, K. E., Wong, P. K., & Liao, J. C. (2014) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.2014.888313 · Cited by 435
Metadata
- Authors
- Soelberg, S. D., Stevens, R. C., Limaye, A. P., & Furlong, C. E.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-02-12
- Volume
- 81
- Issue
- 6
- Pages
- 2357-2363
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2104987759
- Cited by
- 174
- References
- 1
- FWCI
- 5.76
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.