Stevens, Richard C., Soelberg, Scott D., Near, Steve, Furlong, Clement E.·2008·Analytical Chemistry

Abstract

Saliva provides a useful and noninvasive alternative to blood for many biomedical diagnostic assays. The level of the hormone cortisol in blood and saliva is related to the level of stress. We present here the development of a portable surface plasmon resonance (SPR) biosensor system for detection of cortisol in saliva. Cortisol-specific monoclonal antibodies were used to develop a competition assay with a six-channel portable SPR biosensor designed in our laboratory. The detection limit of cortisol in laboratory buffers was 0.36 ng/mL (1.0 nM). An in-line filter based on diffusion through a hollow fiber hydrophilic membrane served to separate small molecules from the complex macromolecular matrix of saliva prior to introduction to the sensor surface. The filtering flow cell provided in-line separation of small molecules from salivary mucins and other large molecules with only a 29% reduction of signal compared with direct flow of the same concentration of analyte over the sensor surface. A standard curve for detection of cortisol in saliva was generated with a detection limit of 1.0 ng/mL (3.6 nM), sufficiently sensitive for clinical use. The system will also be useful for a wide range of applications where small molecular weight analytes are found in complex matrixes.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac800892h

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Because saliva can be readily collected, it has been used in connection to in vitro diagnostic biosensors on strips or portable device platforms.

    “Because saliva can be readily collected123-125, it has been used in connection to in vitro diagnostic biosensors on strips or portable device platforms,126-134.”

    From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [127]

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 4

  1. [3]Higazi AR Ata AH J Egypt Med Assoc 1958 41 71 84 13575627
  2. [11]Kirschbaum C Hellhammer DH Fink G Encyclopedia of Stress 3 Academic Press San Diego 2000 379 383
  3. [15]Westermann J Demir A Herbst V Clin Lab 2004 50 11 24 15000217
  4. [30]Furlong CE Stevens RC Soelberg SD Yee N Geiss G Katze MG Near S Yee S Chinowsky T Winder C Proceedings of a Conference, held at Imperial College, London, 20–21 April 2005 University of New South Wales Sydney 2005 255 270

Cited by

Sorted by citations

Authors
Stevens, R. C., Soelberg, S. D., Near, S., & Furlong, C. E.
Affiliations
University of Washington (US)
Corresponding author
Furlong, Clement E.
Venue
Analytical Chemistry
Published
2008-07-26
Volume
80
Issue
17
Pages
6747-6751
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W1977790675
Cited by
179
References
30
Citations by year
2026: 7 · 2025: 13 · 2024: 16 · 2023: 13 · 2022: 9 · 2021: 12 · 2020: 14 · 2019: 9 · 2018: 14 · 2017: 2 · 2016: 7 · 2015: 9 · 2014: 8 · 2013: 10 · 2012: 12
FWCI
5.30
Type
journal article
Language
en
Open access
Locations
  • Analytical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
  • PubMed Central (acceptedVersion)
Funders
  • National Science Foundation
  • National Institutes of Health
  • National Institute of Environmental Health Sciences (P50ES012762)
  • National Institute of Dental and Craniofacial Research (1-UO1DE14971, U01DE014971)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Plasmonic and Surface Plasmon Research
  • Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced Biosensing Techniques and Applications
Keywords
cortisol, saliva, surface plasmon resonance biosensor, portable biosensor, hollow fiber membranes, competitive immunoassay, monoclonal antibodies, salivary mucins, stress biomarkers
MeSH terms
Buffers, Humans, Hydrocortisone, Molecular Weight, Saliva, Surface Properties, Surface Plasmon Resonance

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review