Photoactivated CdTe/CdSe Quantum Dots as a Near Infrared Fluorescent Probe for Detecting Biothiols in Biological Fluids
Abstract
The important roles of biothiols in biological systems have attracted great interest in the determination of biothiols. Although great progress has been made in fluorescent biothiol probes, near-infrared (NIR) fluorescent probes for biothiols are rather few even such NIR probes can avoid interference from biological media such as tissue autofluorescence and scattering light, and thereby facilitate relatively interference-free sensing. Herein, we report photoactivated CdTe/CdSe quantum dots (QDs) as a novel NIR fluorescent probe for biothiols. The photoactivated CdTe/CdSe QDs based NIR fluorescent probe offers good sensitivity and selectivity for detecting cysteine (Cys), homocysteine (Hcy), and glutathione (GSH) in the presence of 20 other amino acids, main relevant metal ions, and some other molecules in biological fluids. The recovery of spiked 5.0 microM thiols in human urine, plasma, and cell extracts ranges from 90% to 109%. The precision for nine replicate measurements of the thiols at 5.0 microM is in the range from 1.6% to 1.8%. The detection limits for Cys, Hcy, and GSH are 131, 26, and 20 nM, respectively. This assay is based on both the superior photoactivity of CdTe/CdSe QDs and the strong affinity of thiols to photoactivated CdTe/CdSe QDs. The addition of thiols into the photoactivated CdTe/CdSe QDs improves the passivation of the illumination-induced traps, meanwhile reduces most of Se(IV) and Te(IV) on the surface of photoactivated CdTe/CdSe QDs so as to improve the fluorescence property.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Plasma Homocysteine as a Risk Factor for Dementia and Alzheimer's Disease
Seshadri, S., Beiser, A., Selhub, J., Jacques, P. F., Rosenberg, I. H., D'Agostino, R. B., Wilson, P. W. F., & Wolf, P. A. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa011613 · Cited by 3,237
Homocysteine and Cardiovascular Disease
Refsum, H., Ueland, P. M., Nygård, O., & Vollset, S. E. (1998) · Annual Review of Medicine · doi:10.1146/annurev.med.49.1.31 · Cited by 2,180
Glutathione Deficiency and Human Immunodeficiency Virus Infection
Staal, F. J. T., Ela, S. W., Roederer, M., Anderson, M. T., Herzenberg, L. A., & Herzenberg, L. A. (1992) · The Lancet · doi:10.1016/0140-6736(92)90939-z · Cited by 404
Cited by
Zhang, X.-L., Zheng, C., Guo, S.-S., Li, J., Yang, H.-H., & Chen, G. (2014) · Analytical Chemistry · doi:10.1021/ac500336f · Cited by 414
Wu, P., He, Y., Wang, H.-F., & Yan, X.-P. (2010) · Analytical Chemistry · doi:10.1021/ac902531g · Cited by 345
Self-citation
Metadata
- Authors
- Zhang, Y., Li, Y., & Yan, X.-P.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-05-13
- Volume
- 81
- Issue
- 12
- Pages
- 5001-5007
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2066512350
- Cited by
- 180
- References
- 3
- FWCI
- 8.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Photoactivated CdTe/CdSe Quantum Dots as a Near Infrared Fluorescent Probe for Detecting Biothiols in Biological Fluids. https://app.cochat.ai/papers/10.1021/ac900394e
- The paper
- Zhang, Y., Li, Y., & Yan, X.-P. (2009). Photoactivated CdTe/CdSe Quantum Dots as a Near Infrared Fluorescent Probe for Detecting Biothiols in Biological Fluids. Analytical Chemistry. https://doi.org/10.1021/ac900394e
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.