The DOI matches its Crossref record.
Simultaneous Electrochemical Determination of Glutathione and Glutathione Disulfide at a Nanoscale Copper Hydroxide Composite Carbon Ionic Liquid Electrode
Abstract
Direct simultaneous electrochemical determination of glutathione (GSH) and glutathione disulfide (GSSG) has been presented using a nanoscale copper hydroxide carbon ionic liquid composite electrode. To the best of our knowledge, this is the first report on the simultaneous determination of these two biologically important compounds based on their direct electrochemical oxidation. Incorporation of copper(II) hydroxide nanostructures in the composite electrode results in complexation of Cu(II) with the thiol group of GSH and leads to a significant decrease in GSH oxidation overpotential, while an anodic peak corresponding to the direct oxidation of GSSG as the product of GSH oxidation is observed at higher overvoltages. Low detection limits of 30 nM for GSH and 15 nM for GSSG were achieved based on a signal-to-noise ratio of 3. The proposed method is free from interference of cysteine, homocysteine, ascorbic acid (AA), and uric acid (UA). No electrode surface fouling was observed during successive scans. Stability, high sensitivity, and low detection limits made the proposed electrode applicable for the analysis of biological fluids.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ionic liquids in analytical chemistry
Sun, P., & Armstrong, D. W. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.12.007 · Cited by 727
Zhang, X.-L., Zheng, C., Guo, S.-S., Li, J., Yang, H.-H., & Chen, G. (2014) · Analytical Chemistry · doi:10.1021/ac500336f · Cited by 414
Application of ionic liquids in electrochemical sensing systems
Shiddiky, M. J. A., & Torriero, A. A. J. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.08.064 · Cited by 408
Ionic liquids in surface electrochemistry
Liu, H., Liu, Y., & Li, J. (2010) · Physical Chemistry Chemical Physics · doi:10.1039/b921469k · Cited by 372
A review on electrodes modified with ionic liquids
Opallo, M., & Lesniewski, A. (2011) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2011.01.008 · Cited by 351
Metadata
- Authors
- Safavi, A., Maleki, N., Farjami, E., & Mahyari, F. A.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-08-14
- Volume
- 81
- Issue
- 18
- Pages
- 7538-7543
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2064783756
- Cited by
- 182
- References
- 0
- FWCI
- 9.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Simultaneous Electrochemical Determination of Glutathione and Glutathione Disulfide at a Nanoscale Copper Hydroxide Composite Carbon Ionic Liquid Electrode. https://app.cochat.ai/papers/10.1021/ac900501j
- The paper
- Safavi, A., Maleki, N., Farjami, E., & Mahyari, F. A. (2009). Simultaneous Electrochemical Determination of Glutathione and Glutathione Disulfide at a Nanoscale Copper Hydroxide Composite Carbon Ionic Liquid Electrode. Analytical Chemistry. https://doi.org/10.1021/ac900501j
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.