Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 221

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

CdTe Quantum Dots (QDs) Based Kinetic Discrimination of Fe2+ and Fe3+, and CdTe QDs-Fenton Hybrid System for Sensitive Photoluminescent Detection of Fe2+

Wu, Peng, Li, Yan, Yan, Xiu-Ping·2009·Analytical Chemistry

Abstract

A method based on the quenching kinetics for the fluorescence of glutathione capped CdTe quantum dots (GSH-CdTe QDs) was developed for discriminating Fe 2+ and Fe 3+, and a GSH-CdTe QDs-Fenton hybrid system was constructed for sensitive and selective determination of trace Fe 2+ . Although both Fe 2+ and Fe 3+ could quench the fluorescence of GSH-CdTe QDs, the quenching kinetics was quite different for Fe 2+ and Fe 3+ . The fluorescence of the GSH-CdTe QDs (30 nM) was quenched by about 18% in 1 min after the addition of Fe 3+ (10 μM), and remained unchanged with further increase of reaction time. In contrast, the fluorescence intensity of the GSH-CdTe QDs decreased by about 65% in the first 5 min after the addition of Fe 2+ (10 μM), then slowly decreased by 15% in the next 25 minutes. Other transition metal ions like Cu 2+, Ni 2+ and Co 2+, Zn 2+, and Mn 2+ also gave very different quenching kinetics of the GSH-CdTe QDs from Fe 2+ . No significant effect of the capping agents (GSH, thioglycolic acid, and mercaptopropionic acid) for the QDs on the pattern of the time course of the fluorescence of the QDs for Fe 2+ or Fe 3+ was observed. To achieve selective determination of Fe 2+ in the presence of Fe 3+, trace H 2 O 2 was introduced to establish a QDs-Fenton hybrid system. The Fenton reaction between Fe 2+ and H 2 O 2 resulted in hydroxyl radicals which can effectively quench the fluorescence of the QDs through electron transfer from the conduction band of the QDs to the single occupied molecular orbit of hydroxyl radicals. The high redox potential of hydroxyl radicals (2.8 V) permits more effective quenching of the fluorescence of the QDs than Fe 2+ . The detection limit of the developed method was 5 nM for Fe 2+ . The recovery of Fe 2+ spiked in water samples ranged from 96% to 105%.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac900788w

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 221

Metadata

Authors
Wu, P., Li, Y., & Yan, X.-P.
Venue
Analytical Chemistry
Published
2009-06-24
Volume
81
Issue
15
Pages
6252-6257
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2011366869
Cited by
221
References
1
FWCI
6.06
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: CdTe Quantum Dots (QDs) Based Kinetic Discrimination of Fe2+ and Fe3+, and CdTe QDs-Fenton Hybrid System for Sensitive Photoluminescent Detection of Fe2+. https://app.cochat.ai/papers/10.1021/ac900788w
The paper
Wu, P., Li, Y., & Yan, X.-P. (2009). CdTe Quantum Dots (QDs) Based Kinetic Discrimination of Fe2+ and Fe3+, and CdTe QDs-Fenton Hybrid System for Sensitive Photoluminescent Detection of Fe2+. Analytical Chemistry. https://doi.org/10.1021/ac900788w

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.