The DOI matches its Crossref record.
Nonenzymatic Electrochemical Detection of Glucose Based on Palladium−Single-Walled Carbon Nanotube Hybrid Nanostructures
Abstract
A new electrocatalyst, palladium nanoparticle-single-walled carbon nanotube (Pd-SWNTs) hybrid nanostructure, for the nonenzymatic oxidation of glucose was developed and characterized by X-ray diffraction (XRD) and the transmission electron microscope (TEM). The hybrid nanostructures were prepared by depositing palladium nanoparticles with average diameters of 4-5 nm on the surface of single-walled carbon nanotubes (SWNTs) via chemical reduction of the precursor (Pd(2+)). The electrocatalyst showed good electrocatalytic activity toward the oxidation of glucose in the neutral phosphate buffer solution (PBS, pH 7.4) even in the presence of a high concentration of chloride ions. A nonenzymatic amperometric glucose sensor was developed with the use of the Pd-SWNT nanostructure as an electrocatalyst. The sensor had good electrocatalytic activity toward oxidation of glucose and exhibited a rapid response (ca.3 s), a low detection limit (0.2 +/- 0.05 microM), a wide and useful linear range (0.5-17 mM), and high sensitivity (approximately 160 microA mM(-1) cm(-2)) as well as good stability and repeatability. In addition, the common interfering species, such as ascorbic acid, uric acid, 4-acetamidophenol, 3,4-dihydroxyphenylacetic acid, and so forth did not cause any interference due to the use of a low detection potential (-0.35 V vs SCE). The sensor can also be used for quantification of the concentration of glucose in real clinical samples. Therefore, this work has demonstrated a simple and effective sensing platform for nonenzymatic detection of glucose.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A Comprehensive Review of Glucose Biosensors Based on Nanostructured Metal-Oxides
Rahman, M. M., Ahammad, A. J. S., Jin, J.-H., Ahn, S. J., & Lee, J.-J. (2010) · Sensors · doi:10.3390/s100504855 · Cited by 762
Self-citationZhu, C., Du, D., Eychmüller, A., & Lin, Y. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00255 · Cited by 672
Advances in carbon nanotube based electrochemical sensors for bioanalytical applications
Vashist, S. K., Zheng, D., Al-Rubeaan, K., Luong, J. H. T., & Sheu, F.-S. (2011) · Biotechnology Advances · doi:10.1016/j.biotechadv.2010.10.002 · Cited by 448
Metadata
- Authors
- Meng, L., Jin, J., Yang, G., Lu, T., Zhang, H., & Cai, C.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-08-10
- Volume
- 81
- Issue
- 17
- Pages
- 7271-7280
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1989823938
- Cited by
- 412
- References
- 0
- FWCI
- 26.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.