The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Highly Sensitive Electrochemical Sensor for Mercury(II) Ions by Using a Mercury-Specific Oligonucleotide Probe and Gold Nanoparticle-Based Amplification
Abstract
We report a highly sensitive electrochemical sensor for the detection of Hg(2+) ions in aqueous solution by using a thymine (T)-rich, mercury-specific oligonucleotide (MSO) probe and gold nanoparticles (Au NPs)-based signal amplification. The MSO probe contains seven thymine bases at both ends and a "mute" spacer in the middle, which, in the presence of Hg(2+), forms a hairpin structure via the Hg(2+)-mediated coordination of T-Hg(2+)-T base pairs. The thiolated MSO probe is immobilized on Au electrodes to capture free Hg(2+) in aqueous media, and the MSO-bound Hg(2+) can be electrochemically reduced to Hg(+), which provides a readout signal for quantitative detection of Hg(2+). This direct immobilization strategy leads to a detection limit of 1 microM. In order to improve the sensitivity, MSO probe-modified Au NPs are employed to amplify the electrochemical signals. Au NPs are comodified with the MSO probe and a linking probe that is complementary to a capture DNA probe immobilized on gold electrodes. We demonstrated that this Au NPs-based sensing strategy brings about an amplification factor of more than 3 orders of magnitude, leading to a limit of detection of 0.5 nM (100 ppt), which satisfactorily meets the sensitivity requirement of U.S. Environmental Protection Agency (EPA). This Au NPs-based Hg(2+) sensor also exhibits excellent selectivity over a spectrum of interference metal ions. Considering the high sensitivity and selectivity of this sensor, as well as the cost-effective and portable features of electrochemical techniques, we expect this Au NPs amplified electrochemical sensor will be a promising candidate for field detection of environmentally toxic mercury.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zhang, J., Song, S., Zhang, L., Wang, L., Wu, H., Pan, D., & Fan, C. (2006) · Journal of the American Chemical Society · doi:10.1021/ja061521a · Cited by 424
Self-citation
Cited by
A Self‐Powered Triboelectric Nanosensor for Mercury Ion Detection
Lin, Z., Zhu, G., Zhou, Y. S., Yang, Y., Bai, P., Chen, J., & Wang, Z. L. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201300437 · Cited by 371
Ratiometric Detection of Cr3+and Hg2+by a Naphthalimide-Rhodamine Based Fluorescent Probe
Mahato, P., Saha, S., Suresh, E., Di Liddo, R., Parnigotto, P. P., Conconi, M. T., Kesharwani, M. K., Ganguly, B., & Das, A. (2012) · Inorganic Chemistry · doi:10.1021/ic202073q · Cited by 319
Metadata
- Authors
- Zhu, Z., Su, Y., Li, J., Li, D., Zhang, J., Song, S., Zhao, Y., Li, G., & Fan, C.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-08-19
- Volume
- 81
- Issue
- 18
- Pages
- 7660-7666
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2092389482
- Cited by
- 431
- References
- 1
- FWCI
- 14.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Highly Sensitive Electrochemical Sensor for Mercury(II) Ions by Using a Mercury-Specific Oligonucleotide Probe and Gold Nanoparticle-Based Amplification. https://app.cochat.ai/papers/10.1021/ac9010809
- The paper
- Zhu, Z., Su, Y., Li, J., Li, D., Zhang, J., Song, S., Zhao, Y., Li, G., & Fan, C. (2009). Highly Sensitive Electrochemical Sensor for Mercury(II) Ions by Using a Mercury-Specific Oligonucleotide Probe and Gold Nanoparticle-Based Amplification. Analytical Chemistry. https://doi.org/10.1021/ac9010809
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.