The DOI matches its Crossref record.
Using Aptamer-Conjugated Fluorescence Resonance Energy Transfer Nanoparticles for Multiplexed Cancer Cell Monitoring
Abstract
To facilitate the selection of effective therapeutic pathways and improve clinical outcomes, sensitive and simultaneous diagnosis of multiple trace biomarkers or cancer cells from complex living samples is particularly critical in the early stages of tumor development. To achieve this, we have combined the selectivity and affinity of aptamers with the spectroscopic advantages of fluorescence resonance energy transfer (FRET) nanoparticles (NPs). This has produced an aptamer-conjugated FRET NP assay that performs simultaneous multiplexed monitoring of cancer cells with the desired degree of sensitivity and selectivity. First, by changing the doping ratio of three different dyes, the FRET-mediated emission signatures could be tuned such that the nanoparticles would exhibit multiple colors upon excitation with a single wavelength. These FRET nanoparticles were then modified by a few aptamers specific for different cancer cell lines, in this case, T-cell leukemia and B-cell lymphoma. As a result, simultaneous and sensitive detection of multiple cancer cell targets was achieved. Therefore, our aptamer-conjugated FRET NPs are highly promising for potential applications in the sensitive monitoring of multiple cancer cells for biomedical research and medical diagnostics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Aptamers from Cell-Based Selection for Bioanalytical Applications
Tan, W., Donovan, M. J., & Jiang, J. (2013) · Chemical Reviews · doi:10.1021/cr300468w · Cited by 649
Self-citationPrecise nanomedicine for intelligent therapy of cancer
Chen, H., Gu, Z., An, H., Chen, C., Chen, J., Cui, R., Chen, S., Chen, W., Chen, X., Chen, X., et al. (2018) · Science China Chemistry · doi:10.1007/s11426-018-9397-5 · Cited by 409
Self-citationDNA Nanoflowers for Multiplexed Cellular Imaging and Traceable Targeted Drug Delivery
Hu, R., Zhang, X., Zhao, Z., Zhu, G., Chen, T., Fu, T., & Tan, W. (2014) · Angewandte Chemie International Edition · doi:10.1002/anie.201400323 · Cited by 337
Self-citationWen, Y., Pei, H., Wan, Y., Su, Y., Huang, Q., Song, S., & Fan, C. (2011) · Analytical Chemistry · doi:10.1021/ac201491p · Cited by 265
Kotha, R., Fernandes, G., Nikam, A. N., Kulkarni, S., Pandey, A., Pandey, S., & Mutalik, S. (2020) · Materials Science and Technology · doi:10.1080/02670836.2020.1832323 · Cited by 17
Metadata
- Authors
- Chen, X., Estévez, M.-C., Zhu, Z., Huang, Y.-F., Chen, Y., Wang, L., & Tan, W.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-07-02
- Volume
- 81
- Issue
- 16
- Pages
- 7009-7014
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2012112777
- Cited by
- 159
- References
- 0
- FWCI
- 7.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Using Aptamer-Conjugated Fluorescence Resonance Energy Transfer Nanoparticles for Multiplexed Cancer Cell Monitoring. https://app.cochat.ai/papers/10.1021/ac9011073
- The paper
- Chen, X., Estévez, M.-C., Zhu, Z., Huang, Y.-F., Chen, Y., Wang, L., & Tan, W. (2009). Using Aptamer-Conjugated Fluorescence Resonance Energy Transfer Nanoparticles for Multiplexed Cancer Cell Monitoring. Analytical Chemistry. https://doi.org/10.1021/ac9011073
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.