The DOI matches its Crossref record.
Particle Focusing Mechanisms in Curving Confined Flows
Abstract
Particles in finite-inertia confined channel flows are known to segregate and focus to equilibrium positions whose number corresponds with the fold of symmetry of the channel's cross section. The addition of curvature into channels presumably modifies these equilibrium inertial focusing positions, because of the secondary flow induced in curved channels. Here, we identify the critical interaction of the secondary flow field with inertial lift forces to create complex sets of particle focusing positions that vary with the channel Reynolds number (Re(C)) and the inertial force ratio, which is a new dimensionless parameter that is based on the ratio of inertial lift to drag forces from the secondary flow. We use these results to identify microfluidic channel geometries to focus particles at rates an order of magnitude higher than previously shown (channel Reynolds number, Re(C) = 270) and develop design criteria for the focusing of potentially arbitrary-sized particles. In addition, our results indicate that channel curvature can lead to microfluidic designs with reduced fluidic resistance, useful for lower power inertial focusing or separation. These results will enable design of practical particle/cell separation, filtration, and focusing systems for critical applications in biomedicine and environmental cleanup.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Di Carlo, D. (2009) · Lab on a Chip · doi:10.1039/b912547g · Cited by 1,627
Fundamentals and applications of inertial microfluidics: a review
Zhang, J., Yan, S., Yuan, D., Alici, G., Nguyen, N.-T., Ebrahimi Warkiani, M., & Li, W. (2016) · Lab on a Chip · doi:10.1039/c5lc01159k · Cited by 1,017
Label-free cell separation and sorting in microfluidic systems
Gossett, D. R., Weaver, W. M., Mach, A. J., Hur, S. C., Tse, H. T. K., Lee, W., Amini, H., & Di Carlo, D. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3721-9 · Cited by 930
Self-citationAmini, H., Lee, W., & Di Carlo, D. (2014) · Lab on a Chip · doi:10.1039/c4lc00128a · Cited by 722
Slanted spiral microfluidics for the ultra-fast, label-free isolation of circulating tumor cells
Warkiani, M. E., Guan, G., Luan, K. B., Lee, W. C., Bhagat, A. A. S., Kant Chaudhuri, P., Tan, D. S.-W., Lim, W. T., Lee, S. C., Chen, P. C. Y., et al. (2014) · Lab Chip · doi:10.1039/c3lc50617g · Cited by 573
Metadata
- Authors
- Gossett, D. R., & Carlo, D. D.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-09-17
- Volume
- 81
- Issue
- 20
- Pages
- 8459-8465
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2008952870
- Cited by
- 246
- References
- 0
- FWCI
- 7.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Particle Focusing Mechanisms in Curving Confined Flows. https://app.cochat.ai/papers/10.1021/ac901306y
- The paper
- Gossett, D. R., & Carlo, D. D. (2009). Particle Focusing Mechanisms in Curving Confined Flows. Analytical Chemistry. https://doi.org/10.1021/ac901306y
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.