The DOI matches its Crossref record.
Stripping Voltammetric Detection of Mercury(II) Based on a Bimetallic Au−Pt Inorganic−Organic Hybrid Nanocomposite Modified Glassy Carbon Electrode
Abstract
A new, highly sensitive and selective sensor for the electrochemical assay of Hg(II) by anodic stripping voltammetry has been developed, whereby a glassy carbon electrode is modified with a novel inorganic-organic hybrid nanocomposite, namely, bimetallic Au-Pt nanoparticles/organic nanofibers (labeled as Au-PtNPs/NFs). The sensor possesses a three-dimensional (3D) porous network nanoarchitecture, in which the bimetallic Au-Pt NPs serving as metal NP-based microelectrode ensembles are homogenously distributed in the matrix of interlaced organic NFs. The surface structure and composition of the sensor were characterized by scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS). Its electrochemical performance was systematically investigated. Our results show that such a newly designed, Au-PtNPs/NF nanohybrid modified electrode provides remarkably improved sensitivity and selectivity for the stripping assay of Hg(II). The detection limit is found to be as low as 0.008 ppb (S/N = 3) that is much below the guideline value from the World Health Organization (WHO). Interferences from other heavy metal ions such as Cu(II), Cr(III), Co(II), Fe(II), Zn(II), and Mn(II) ions associated with mercury analysis are effectively inhibited. Toward the goal for practical applications, the sensor was further evaluated by monitoring Hg(II) in tap and river water specimens.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Electrochemical sensing of heavy metal ions with inorganic, organic and bio-materials
Cui, L., Wu, J., & Ju, H. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.07.052 · Cited by 613
Recent advances in nanomaterials for water protection and monitoring
Das, R., Vecitis, C. D., Schulze, A., Cao, B., Ismail, A. F., Lu, X., Chen, J., & Ramakrishna, S. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00921b · Cited by 552
Ariya, P. A., Amyot, M., Dastoor, A., Deeds, D., Feinberg, A., Kos, G., Poulain, A., Ryjkov, A., Semeniuk, K., Subir, M., et al. (2015) · Chemical Reviews · doi:10.1021/cr500667e · Cited by 453
Nanomaterials application in electrochemical detection of heavy metals
Aragay, G., & Merkoçi, A. (2012) · Electrochimica Acta · doi:10.1016/j.electacta.2012.04.044 · Cited by 402
Zhang, W., Zhu, S., Luque, R., Han, S., Hu, L., & Xu, G. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00297d · Cited by 313
Theerthagiri, J., Lee, S. J., Karuppasamy, K., Park, J., Yu, Y., Kumari, M. L. A., Chandrasekaran, S., Kim, H.-S., & Choi, M. Y. (2021) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2021.126648 · Cited by 85
Metadata
- Authors
- Gong, J., Zhou, T., Song, D., Zhang, L., & Hu, X.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-12-16
- Volume
- 82
- Issue
- 2
- Pages
- 567-573
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1990299624
- Cited by
- 222
- References
- 0
- FWCI
- 11.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.