Development of Mass Spectrometry-Based Shotgun Method for Proteome Analysis of 500 to 5000 Cancer Cells
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A shotgun proteome analysis method and its performance for protein identification from 500 to 5000 cells are described. Sample preparation, which was done in one tube, involved the use of a surfactant (NP-40) for cell lysis, followed by acetone precipitation of the proteins. The resulting protein pellet was washed with cold acetone to remove remaining surfactant, and the pellet was then solubilized in NH(4)HCO(3). After trypsin digestion of the proteins, the digest was analyzed by the use of nanoflow liquid chromatography (LC) quadrupole time-of-flight mass spectrometry (QTOF MS). Sample injection and gradient speed in running LC QTOF MS were optimized. It was shown that this method could identify an average (n = 3) of 167 +/- 21, 237 +/- 30, 491 +/- 63, and 619 +/- 59 proteins from 500, 1000, 2500, and 5000 MCF-7 breast cancer cells, respectively. To demonstrate the potential use of this method for generating proteome profile from circulating tumor cells (CTCs) isolated from human blood, a healthy human blood sample was spiked with MCF-7 cells, and this mixture was processed and then subjected to antibody tagging of the MCF-7 cells. The tagged cells were sorted and collected using flow cytometry. The proteome profiles of small numbers of cells isolated in this way were found to be similar to those of the original MCF-7 cells, suggesting the possibility of the use of this method for cell typing of CTCs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Elias, J. E., & Gygi, S. P. (2007) · Nature Methods · doi:10.1038/nmeth1019 · Cited by 3,925
Proteomics of Integral Membrane ProteinsTheory and Application
Speers, A. E., & Wu, C. C. (2007) · Chemical Reviews · doi:10.1021/cr068286z · Cited by 325
Cited by
Protein Analysis by Shotgun/Bottom-up Proteomics
Zhang, Y., Fonslow, B. R., Shan, B., Baek, M.-C., & Yates, J. R. (2013) · Chemical Reviews · doi:10.1021/cr3003533 · Cited by 1,491
Ultrasensitive proteome analysis using paramagnetic bead technology
Hughes, C. S., Foehr, S., Garfield, D. A., Furlong, E. E., Steinmetz, L. M., & Krijgsveld, J. (2014) · Molecular Systems Biology · doi:10.15252/msb.20145625 · Cited by 1,225
Zhu, Y., Piehowski, P. D., Zhao, R., Chen, J., Shen, Y., Moore, R. J., Shukla, A. K., Petyuk, V. A., Campbell-Thompson, M., Mathews, C. E., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-03367-w · Cited by 587
Mass spectrometry-based proteomics: existing capabilities and future directions
Angel, T. E., Aryal, U. K., Hengel, S. M., Baker, E. S., Kelly, R. T., Robinson, E. W., & Smith, R. D. (2012) · Chemical Society Reviews · doi:10.1039/c2cs15331a · Cited by 441
Wiśniewski, J. R., Ostasiewicz, P., & Mann, M. (2011) · Journal of Proteome Research · doi:10.1021/pr200019m · Cited by 290
Metadata
- Authors
- Wang, N., Xu, M., Wang, P., & Li, L.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-01-21
- Volume
- 82
- Issue
- 6
- Pages
- 2262-2271
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2010197017
- Cited by
- 80
- References
- 2
- FWCI
- 3.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.