The DOI matches its Crossref record.
Development, Characterization, and Application of Paper Spray Ionization
Abstract
Paper spray is developed as a direct sampling ionization method for mass spectrometric analysis of complex mixtures. Ions of analyte are generated by applying a high voltage to a paper triangle wetted with a small volume (<10 microL) of solution. Samples can be preloaded onto the paper, added with the wetting solution, or transferred from surfaces using the paper as a wipe. It is demonstrated that paper spray is applicable to the analysis of a wide variety of compounds, including small organic compounds, peptides, and proteins. Procedures are developed for analysis of dried biofluid spots and applied to therapeutic drug monitoring with whole blood samples and to illicit drug detection in raw urine samples. Limits of detection of 50 ng/mL (or 20 pg absolute) are achieved for atenolol in bovine blood. The combination of sample collection from surfaces and paper spray ionization also enables fast chemical screening at high sensitivity, for example 100 pg of heroin distributed on a surface and agrochemicals on fruit peels are detectable. Online derivatization with a preloaded reagent is demonstrated for analysis of cholesterol in human serum. The combination of paper spray with miniature mass spectrometers offers a powerful impetus to wide application of mass spectrometry in nonlaboratory environments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ambient Sampling/Ionization Mass Spectrometry: Applications and Current Trends
Harris, G. A., Galhena, A. S., & Fernández, F. M. (2011) · Analytical Chemistry · doi:10.1021/ac200918u · Cited by 527
Miniature and Fieldable Mass Spectrometers: Recent Advances
Snyder, D. T., Pulliam, C. J., Ouyang, Z., & Cooks, R. G. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b03070 · Cited by 420
Self-citationTherapeutic Drug Monitoring by Dried Blood Spot: Progress to Date and Future Directions
Wilhelm, A. J., den Burger, J. C. G., & Swart, E. L. (2014) · Clinical Pharmacokinetics · doi:10.1007/s40262-014-0177-7 · Cited by 342
Ambient mass spectrometry: bringing MS into the “real world”
Alberici, R. M., Simas, R. C., Sanvido, G. B., Romão, W., Lalli, P. M., Benassi, M., Cunha, I. B. S., & Eberlin, M. N. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3808-3 · Cited by 340
Souza-Silva, É. A., Jiang, R., Rodríguez-Lafuente, A., Gionfriddo, E., & Pawliszyn, J. (2015) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.04.016 · Cited by 335
Applications of Mass Spectrometry for Clinical Diagnostics: The Influence of Turnaround Time
Swiner, D. J., Jackson, S., Burris, B. J., & Badu-Tawiah, A. K. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b04901 · Cited by 73
Smith, R., Brookes, C., Morris, M., & Barran, P. (2025) · Analytical Chemistry · doi:10.1021/acs.analchem.5c02331 · Cited by 14
Metadata
- Authors
- Liu, J., Wang, H., Manicke, N. E., Lin, J.-M., Cooks, R. G., & Ouyang, Z.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-02-16
- Volume
- 82
- Issue
- 6
- Pages
- 2463-2471
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2052474968
- Cited by
- 711
- References
- 0
- FWCI
- 12.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.