Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 168

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Glucose-Sensing Electrode Coated with Polymer Complex Gel Containing Phenylboronic Acid

Kikuchi, Akihiko, Suzuki, Ken, Okabayashi, Osamu, Hoshino, Hiroshi, Kataoka, Kazunori, Sakurai, Yasuhisa, Okano, Teruo·1996·Analytical Chemistry

Abstract

We have prepared a copolymer containing both phenylboronic acid and tertiary amine moieties. The copolymer forms a stable complex with poly(vinyl alcohol) (PVA) since boronate moieties interact with PVA hydroxyl groups. The polymer-polymer complex changes its swelling degree with glucose concentration in Dulbecco's phosphate-buffered saline solution (PBS) at pH 7.4, due to the higher complex formation of boronic acid moieties with glucose hydroxyl groups over those in PVA. Glucose-responsive swelling changes of a membrane complex were then utilized to control glucose-responsive current changes with a membrane-coated platinum electrode. Glucose addition to PBS induces swelling of the cast gel membrane, leading to increased diffusion of ion species and thus increased measurable current changes. Since the addition of methyl α-d-glucoside has little influence on the current changes, the current change by the addition of glucose is indicative of the high selectivity of this system for glucose and its cis-hydroxyl groups in glucose. It is observed that current changes are proportional to glucose concentration in the range 0-300 mg/dL. This range corresponds well to physiological blood glucose levels. Current change rates determined from the slope of the time course immediately after glucose addition are also proportional to glucose concentration within this range, yielding even higher sensitivity to the change in glucose concentration. Reproducible signal output is also demonstrated by repetitive, stepwise glucose concentration changes. These results support the applicability of the platinum electrode coated with the gel membrane complex comprising a phenylboronic acid-containing polymer and PVA for a novel glucose-sensing device.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac950748d

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 168

Metadata

Authors
Kikuchi, A., Suzuki, K., Okabayashi, O., Hoshino, H., Kataoka, K., Sakurai, Y., & Okano, T.
Venue
Analytical Chemistry
Published
1996-03-01
Volume
68
Issue
5
Pages
823-828
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2071856508
Cited by
168
References
1
FWCI
6.31
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.