Design and in vitro studies of a needle-type glucose sensor for subcutaneous monitoring

Open access
Bindra, Dilbir S., Zhang, Yanan., Wilson, George S., Sternberg, Robert., Thevenot, Daniel R., Moatti, Dinah., Reach, Gerard.·1991·Analytical Chemistry

Abstract

A new miniaturized glucose oxidase based needle-type glucose microsensor has been developed for subcutaneous glucose monitoring. The sensor is equivalent in shape and size to a 26-guage needle (0.45-mm o.d.) and can be implanted with ease without any incision. The novel configuration greatly facilitates the deposition of enzyme and polymer films so that sensors with characteristics suitable for in vivo use (upper limit of linear range greater than 15 mM, response time less than 5 min, and sensitivity yielding a 5:1 signal-to-background ratio at normal basal glucose levels) can be prepared in high yield (greater than 60%). The sensor response is largely independent of oxygen tension in the normal physiological range. It also exhibits good selectivity against common interferences except for the exogenous drug acetaminophen.

Integrity signals

Registry

Crossref · 10.1021/ac00017a008

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Tecoflex SG-85A polyurethane membranes on needle-type glucose sensors in rats after 30 h provided the biocompatibility often seen with polyurethane and ensured ideal sensor performance by limiting glucose diffusion.

    “The Tecoflex SG-85A membrane provided the biocompatibility often observed with polyurethane while also ensuring ideal sensor performance by limiting glucose diffusion.34”

Cites

Flagged first, then by citations

1 of the 20 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Authors
Bindra, D. S., Zhang, Y., Wilson, G. S., Sternberg, R., Thevenot, D. R., Moatti, D., & Reach, G.
Affiliations
University of Kansas (US)
Venue
Analytical Chemistry
Published
1991-09-01
Volume
63
Issue
17
Pages
1692-1696
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2009880265
Cited by
309
References
20
Citations by year
2025: 1 · 2024: 7 · 2023: 2 · 2022: 5 · 2021: 5 · 2020: 5 · 2019: 8 · 2018: 4 · 2017: 9 · 2016: 12 · 2015: 9 · 2014: 3 · 2013: 11 · 2012: 10
FWCI
22.25
Type
journal article
Language
en
Open access
Licence
other-oa
Locations
  • Analytical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
  • HAL (submittedVersion, other-oa)
Funders
  • National Institutes of Health (5r01dk030718-12)
  • National Institute of Diabetes and Digestive and Kidney Diseases (DK-30718)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
  • Physical Sciences › Chemical Engineering › Bioengineering › Analytical Chemistry and Sensors
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Enzyme Catalysis and Immobilization
Keywords
glucose oxidase, implantable sensors, polymer films, acetaminophen interference, sensor selectivity, sensor miniaturization
MeSH terms
Animals, Cattle, Glucose, Glucose Oxidase, Biosensing Techniques, In Vitro Techniques

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review