Product Ion Charge State Determination via Ion/Ion Proton Transfer Reactions
The DOI matches its Crossref record.
Abstract
Proton transfer from protonated pyridine to product anions derived from quadrupole ion trap collisional activation of the triply charged anion of the oligonucleotide 5'-d(AAAA)-3' and the 6- charge state of oxidized bovine insulin A-chain is shown to be a rapid and effective way to determine product charge states. The reactions are carried out in a quadrupole ion trap as part of a procedure involving three stages of mass analysis. It is demonstrated that the reactions can be driven at rates sufficiently high to convert 30-80% of the initial product anion population to second generation products in 50-200 ms. The use of ion/ion reactions enjoys significant advantages over the use of ion/molecule proton transfer chemistry. For example, ion/ion reactions are more universal than ion/molecule reactions due to their greater exothermicity, and ion/ion reactions allow for precise control over the timing of introduction and ejection of each reactant. Despite the high exothermicity of the reactions, no significant fragmentation of product ions derived from high-mass multiply charged anions is observed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mass spectrometry of nucleic acids
Nordhoff, E., Kirpekar, F., & Roepstorff, P. (1996) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1996)15:2<67::aid-mas1>3.0.co;2-8 · Cited by 315
‘Top down’ protein characterization via tandem mass spectrometry
Reid, G. E., & McLuckey, S. A. (2002) · Journal of Mass Spectrometry · doi:10.1002/jms.346 · Cited by 285
Self-citationIon/Ion Reactions in the Gas Phase: Proton Transfer Reactions Involving Multiply-Charged Proteins
Stephenson, J. L., & McLuckey, S. A. (1996) · Journal of the American Chemical Society · doi:10.1021/ja9611755 · Cited by 215
Self-citationIon/Ion Proton Transfer Reactions for Protein Mixture Analysis
Stephenson, J. L., & McLuckey, S. A. (1996) · Analytical Chemistry · doi:10.1021/ac9605657 · Cited by 145
Self-citationRecent Developments in Gas-Phase Ion/Ion Reactions for Analytical Mass Spectrometry
Foreman, D. J., & McLuckey, S. A. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b05014 · Cited by 65
Self-citationIon-ion proton transfer reactions of bio-ions involving noncovalent interactions: Holomyoglobin
Stephenson, J. L., Van Berkel, G. J., & McLuckey, S. A. (1997) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(97)00023-8 · Cited by 51
Self-citationIon-ion proton transfer reactions of multiply-charged oligonucleotide cations
Stephenson, J. L., & McLuckey, S. A. (1997) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/s0168-1176(97)00176-6 · Cited by 11
Self-citation
Metadata
- Authors
- Herron, W. J., Goeringer, D. E., & McLuckey, S. A.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1996-01-01
- Volume
- 68
- Issue
- 2
- Pages
- 257-262
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1971346042
- Cited by
- 67
- References
- 0
- FWCI
- 4.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.