The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Instrumental Requirements for Nanoscale Liquid Chromatography
Abstract
Nanoscale liquid chromatography (nano-LC), with packed columns of typically 75 μm i.d. × 15 cm length, packed with C18, 5 μm of stationary phase, and optimal flow rates of 180 nL/min, can be considered as a miniaturized version of conventional HPLC. Using the down-scaling factor, which corresponds to the ratio of the column diameter in square, (d(conv)/d(micro))(2), excellent agreement between the theoretically calculated values and the values obtained using the down-scaling factor (∼3800) has been observed. This factor was applied to all system components, including flow rate, injection and detection volumes, and connecting capillaries. Down-scaling of a conventional HPLC system to a nano-LC system is easy to realize in practice and involves using a microflow processor for nanoflow delivery (50-500 nL/min), a longitudinal nanoflow cell (≤3 nL), a microinjection valve (≤ 20 nL), low-dispersion connecting tubing, and zero dead volume connections. Excellent retention time reproducibility was measured with RSD values of ±0.1% for isocratic and ±0.2% for gradient elution. Plates counts of more than 100 000/m indicate the excellent performance of the entire nano-LC system. With minimal detectable amounts of proteins in the low femtomole and subfemtomole ranges (e.g., 520 amol for bovine serum albumin), high mass sensitivity was found, making nano-LC attractive for the microcharacterization of valuable and/or minute proteinaceous samples. Coupling nano-LC with concomitant mass spectrometry using nanoscale ion spray or electrospray interfaces looks very promising and is obviously the next step for future work.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Int. J. Mass Spectrom. Ion Processes
(1990) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(90)80022-u · Cited by 1,003
Nomenclature for chromatography (IUPAC Recommendations 1993)
Ettre, L. S. (1993) · Pure and Applied Chemistry · doi:10.1351/pac199365040819 · Cited by 651
Barth, H. G., Jackson, C., & Boyes, B. E. (1994) · Analytical Chemistry · doi:10.1021/ac00084a022 · Cited by 220
Karlsson, K. E., & Novotny, M. (1988) · Analytical Chemistry · doi:10.1021/ac00168a006 · Cited by 206
Huczko, E. L., Bodnar, W. M., Benjamin, D., Sakaguchi, K., Zhu, N. Z., Shabanowitz, J., Henderson, R. A., Appella, E., Hunt, D. F., & Engelhard, V. H. (1993) · The Journal of Immunology · doi:10.4049/jimmunol.151.5.2572 · Cited by 169
Chowdhury, S. K., Eshraghi, J., Wolfe, H. R., et al. (1995) · Analytical Chemistry · doi:10.1021/ac00098a026 · Cited by 71
Henzel, W. J., Bourell, J. H., & Stults, J. T. (1990) · Analytical Biochemistry · doi:10.1016/0003-2697(90)90448-i · Cited by 65
Cited by
Analysis of Proteins and Proteomes by Mass Spectrometry
Mann, M., Hendrickson, R. C., & Pandey, A. (2001) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.70.1.437 · Cited by 1,219
Chromatographic Separation Techniques and Data Handling Methods for Herbal Fingerprints: A Review
Tistaert, C., Dejaegher, B., & Heyden, Y. V. (2011) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.02.023 · Cited by 341
Nanoscale LC-MS(n): technical design and applications to peptide and protein analysis
Meiring, H. D., van der Heeft, E., ten Hove, G. J., & de Jong, A. P. J. M. (2002) · Journal of Separation Science · doi:10.1002/1615-9314(20020601)25:9<557::aid-jssc557>3.0.co;2-f · Cited by 267
Metadata
- Authors
- Chervet, J. P., Ursem, M., & Salzmann, J. P.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1996-05-01
- Volume
- 68
- Issue
- 9
- Pages
- 1507-1512
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2006515255
- Cited by
- 268
- References
- 7
- FWCI
- 7.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.